Installing the Main Remote Control:

Electrical Connection

POWER CORD
  

 

 The electric power supply requirement 

for this water heater is 120 vAC/60HZ,  

2 Amps .

 

 A power supply cord is not  supplied with 

the water heater . Use only a power outlet 

with a ground terminal .

 

 The installation of an GFCI (Ground Fault 

Circuit Interrupter) is recommended .

 

 Keep any excess of the power supply cord 

on the outside of the water heater .

 

 If local codes require hardwiring, see 

instructions for “Hardwiring the Electrical 

Connections” .

HARDWIRING 

THE ELECTRICAL CONNECTIONS  

 

 Wiring should be carried out by a qualified 

electrician in accordance with local codes .

 

 The water heater requires 120 vAC/60Hz and 

should be properly grounded .

 

 DO NOT connect grounding wire to water 

pipes, gas pipes, telephone cables, lightning 

conductor circuits and to grounding circuit 

of other equipment that carry a ground-fault 

interrupter .

 

 An ON/OFF switch must be provided and 

installed for the incoming 120vAC power .

 

 Wire the water heater exactly as shown 

below . A wiring diagram is also found 

inside of the cover panel .

 

 A green screw is provided in the junction 

box for a grounding connection .

 

 Connect the live wire to black leg wire and 

the neutral wire to the white neutral wire .

  WARNING: Shock 

hazard line voltage is 

present. Before servicing 

the water heater, turn off 

the electrical power to the 

water heater at the main 

disconnect or circuit 

breaker. Failure to do so 

could result in severe 

personal injury or death.

CAUTION: Label 

all wires prior to 

disconnection when 

servicing controls. Wiring 

errors can cause improper 

and dangerous operation. 

Verify correct operation 

after servicing.

31-93618 0

VERT/JAUNE

G/Y:GREEN/YELLOW,

AC

120V

O:ORANGE,ORANGE

CODE DE COULEUR

COLOR CODE

MIN BUTTON

BOUTON MIN.

G/YorG

W

BOUTON MAX.

BL

BL

BL

LED

G

G

MAX BUTTON ADJUSTER BUTTON

BL

BOUTON DE RÉGLAGE

BL

1

2

3

4

5

A

FOR INDOOR,DIRECT-VENT

MODEL ONLY

POUR MODÈLE INTÉRIEUR À

ÉVENT DIRECT SEULEMENT

4 3 2 1

Y

W

R BK

BL

W BL R O Y

FOR DIRECT-VENT MODEL ONLY

POUR MODÈLE À ÉVENT DIRECT SEULEMENT

SW3

SW2

SW1

U

2

1

S

1

3

2

W

W

1 2 3 4

I

J

H

F

W

W

2 3 4

1

B

R
Y
O

W

BR

BK

1

2

3

4

5

6

7

8

R
Y
O

W

BR

BK

1

2

3

4

5

6

7

8

C

9

R

BR

BK

BK

W

BK

W

1

2

3

4

Y

W

BK

1

2

3

K

SV0

SV1

SV2

SV3

W

BK

W

G/Y

GY

BK

IG

1

2

3

4

5

6

G

FM

5

GY

W

Y

R

R

BK

BK

R

1

2

3

4

5

6

7

+

PSV

R1

R2

R3

R4

BK

BK

-

WIRING DIAGRAM

SCHÉMA DE CÂBLAGE

MOTEUR DU

VENTILATEUR

FAN MOTOR

ELECTRODE

IGNITER

FUSE(3A)

(UMC-117)

CIRCUIT BOARD

PLAQUE DE CIRCUIT

ÉLECTRODE

ALLUMEUR

ANTI-FROST HEATER

CHAUFFAGE ANTI-GIVRE

FUSIBLE(3A)

ON

MARCHE

OFF

ARRÉT

CONTACTEUR DIP 1

DIP SWITCH 1

DIP SWITCH 2

CONTACTEUR DIP 2

ON

MARCHE

OFF

ARRÉT

ÉLECTROVALVE DE DÉRIVATION D'EAU

WATER VOLUME CONTROL MOTOR

WATER BY-PASS CONTROL MOTOR

MOTEUR DE CONTRÔLE DU VOLUME D'EAU

R:RED,ROUGE

W:WHITE,BLANC

BR:BROWN,BRUN

BL:BLUE,BLEU

BK:BLACK,NOIR

GY:GRAY,GRIS

G:GREEN,VERT

Y:YELLOW,JAUNE

BK

(USC1-117)

(USC2-117)

W

W

LIMITER

LIMITEUR

MOTOR

MOTEUR

LIMITER

LIMITEUR

MOTOR

MOTEUR

4

5

6

7

8

GY

R

BL

SV4

BK

BK

BK

BK

1

2

3

V

T

BL

M

W

FLAME ROD 1

ÉLECTRODE DE

DÉTECTION

DE FLAMME 1

FLAME ROD 3

ÉLECTRODE DE

DÉTECTION

DE FLAMME 3

FOR INDOOR,DIRECT-VENT

MODEL ONLY

POUR MODÈLE INTÉRIEUR À

ÉVENT DIRECT SEULEMENT

RÉSISTANCE

USUALLY

DISCONNECTED

NORMALEMENT

DECONNECTE

BK

GND

GND

RESISTOR

SOLENOID VALVE 3

ÉLECTROVALVE 3
SOLENOID VALVE 2

ÉLECTROVALVE 2

ÉLECTROVALVE 1

SOLENOID VALVE 1

ÉLECTROVALVE DANS

ADMISSION DE GAZ

GAS INLET

SOLENOID VALVE 0

OVER HEAT LIMITER

LIMITEUR DE SURCHAUFFE

WATER FLOW SENSOR

D'EAU

CAPTEUR DE DÉBIT

P.G.F.R VALVE

AMBIENT AIR

THERMISTOR

D'AIR AMBIANT

THERMISTOR

DE SORTIE D'EAU CHAUDE

D'ECHANGEUR DE CHALEUR

HOT WATER OUTLET

THERMISTOR

THERMISTOR

HEAT EXCHANGER

THERMISTOR

D'ADMISSION D'EAU

THERMISTOR

WATER INLET

THERMISTOR

THERMISTOR

GAS TYPE

CIRCUIT BOARD

PLAQUE DE CIRCUIT

IMPRIMÉ DE TYPE Â GAZ

MAIN REMOTE

CONTROL

TÉLÉCOMMANDE

<<MAIN>>

BATH REMOTE

CONTROL 1

BATH REMOTE

CONTROL 2

TÉLÉCOMMANDE 1

TÉLÉCOMMANDE 2

<<BATH>>

<<BATH>>

SOLENOID VALVE 4

ÉLECTROVALVE 4

G

G BL

BL

BK R Y O W BR

8

BK R Y O W BR

8

WARNING: Field wiring connections and electrical grounding must comply with local codes, or 

in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70, 

or in Canada, Canadian Electrical Code, CSA C22.1 Part 1.

17

Содержание SCT150X

Страница 1: ...proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manu...

Страница 2: ...heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THIS MANUAL Your safety...

Страница 3: ...e not limited to adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near...

Страница 4: ...achieved with the Bath USC 117 or USC2 117 remote control Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water...

Страница 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Страница 6: ...ntial water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures Have the installer show you the location of t...

Страница 7: ...which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater sh...

Страница 8: ...n How to Obtain Service Assistance Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indication of Important Safety Information...

Страница 9: ...level 12 inches 30 cm above anticipated snow level B Clearance to window or door that may be opened 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 10...

Страница 10: ...accidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticipated snow level 1 8 m If soffit vent is too close block off and install new ven...

Страница 11: ...of 0 66 gpm 2 5 lpm A water pressure of 40 psi 276 kPa is required to achieve maximum flow rate To maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min O...

Страница 12: ...heck Valve between the water heater and the water shutoff valve see the top left diagram The following should be addressed in regards to the HOT WATER OUTLET Connections between the water heater and p...

Страница 13: ...e relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be...

Страница 14: ...of the National Fuel Gas Code In Canada the latest edition of CSA B149 1 Natural Gas and Propane installation code Manual Gas Supply Line Shutoff Manual Gas Appliance Shutoff Union Sediment Trap Cap...

Страница 15: ...nd electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22...

Страница 16: ...r the base plate Ensure the projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control using the screw provided Pro...

Страница 17: ...NTMODELONLY POURMOD LE VENTDIRECTSEULEMENT SW3 SW2 SW1 U 2 1 S 1 3 2 W W 12 3 4 I J H F W W 2 3 4 1 B R Y O W BR BK 1 2 3 4 5 6 7 8 R Y O W BR BK 1 2 3 4 5 6 7 8 C 9 R BR BK BK W BK W 1 2 3 4 Y W BK 1...

Страница 18: ...ufacturer s instructions Outdoor Models Discharge Line To Suitable Drain To Hot Water Faucet s Relief Valve Union Drain Valve 6 15 cm Air Gap Manual Gas Appliance Shut off supplied Flue Terminal Trap...

Страница 19: ...heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused...

Страница 20: ...nd piping Water connections tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated and protected from freezing C Gas Suppl...

Страница 21: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Страница 22: ...s to the water heater If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perfo...

Страница 23: ...above 112 F 44 C when a hot water faucet is in the open position Notice The factory setting allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of 85 F 29 C and up to140 F 60...

Страница 24: ...ater heater discharges periodically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT plug the relief valve outlet R...

Страница 25: ...NOT scrub the appliance with a brush Use only mild soapy water other cleaners may damage the surface of the water heater DO NOT remove any label including the rating plate while cleaning or servicing...

Страница 26: ...ter may be exposed to freezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of vent...

Страница 27: ...Valve Malfunctions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water de...

Страница 28: ...in Gas Line Power supply not grounded Low inlet gas pressure due to improper sizing Wrong gas type Open the Gas shutoff valve fully Contact gas utility company Fill up LP Gas container or replace with...

Страница 29: ...as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring gas piping burners vent connectors or other safety devices Refer repairs to qualified serv...

Страница 30: ...econds Number 120 on the display of the remote control will begin to blink While the number is blinking push the UP arrow temperature adjustment button and the Down arrow temperature adjustment button...

Страница 31: ...ay not function properly NOTICE If the water heater is installed less than 3 280 feet 1 000m no action is required How to adjust the DIP switch on the PCB for high altitude installation Check the alti...

Страница 32: ...act the Manufacturer s National Service Department at the following address 1241 Carwood Court Montgomery AL 36117 Phone 1 800 432 8373 When contacting the manufacturer the following information will...

Отзывы: