Important Comments 

 

 

 Symbols 

 

 

  

WAGO-I/O-SYSTEM 

751 

 

 

AS-Interface Components IP67 

1.2 Symbols 

 

Danger

 

Always abide by this information to protect persons from injury. 

 

Warning

 

Always abide by this information to prevent damage to the device. 

 

Attention

 

Marginal conditions must always be observed to ensure smooth operation. 

 

ESD

 (Electrostatic Discharge) 

Warning of damage to the components by electrostatic discharge. Observe 
the precautionary measure for handling components at risk. 

 

Note

 

Routines or advice for efficient use of the device and software optimization. 

 

More information

 

References on additional literature, manuals, data sheets and INTERNET 
pages 

 

1.3 Number Notation 

Number Code 

Example 

Note 

Decimal 100 

normal 

notation 

Hexadecimal 0x64 

notation 

Binary '100' 

'0110.0100' 

Within ', 
Nibble separated with dots 

 

Содержание I/O-SYSTEM 751-4001

Страница 1: ...AS Interface Components IP67 AS Interface Module 4OUT 24V 2A Single 751 4001 Manual Version 1 1 0...

Страница 2: ...hone 49 0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can...

Страница 3: ...ls 6 1 3 Number Notation 6 1 4 Safety Notes 7 1 5 Scope 7 2 AS Interface Components 8 2 1 AS Interface Module IP67 8 2 1 1 751 4001 AS Interface Module 4OUT 24V 2A Single 8 2 1 1 1 View 8 2 1 1 2 Desc...

Страница 4: ...10e 8 Fig 2 1 1 2 Actuator Connector gqxxx02x 9 Fig 2 1 1 3 Display Elements gq40012x 10 Fig 2 1 1 4 Schematic View gq40011e 11 Fig 2 1 1 5 Dimensions gqxxx08x 14 Fig 2 1 1 6 Assembly gqxxx10x 15 List...

Страница 5: ...ther manufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this...

Страница 6: ...oth operation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for e...

Страница 7: ...ent environment then additional measures are to be taken handling of the components only with clean tools and materials Attention Cleaning of soiled contacts may only be done with ethyl alcohol and le...

Страница 8: ...is an economical solution for a fieldbus independent and flexible connection of actuators from the field and the control cabinet The module is in accordance with AS Interface specification V 3 0 The...

Страница 9: ...cting cable The following table shows the pin assignment of the sockets Tab 2 1 1 1 Actuator Connector Actuator Connectors Connector Pin Function 1 not used 2 not used OUT 1 3 OUT 2 4 3 External volta...

Страница 10: ...t OUT 3 yellow Status DO3 on Output 3 set off Output 4 reset OUT 4 yellow Status DO4 on Output 4 set off OK on Configuration error FID FAULT red Error blinking Actuator supply is missing or output dri...

Страница 11: ...YSTEM 751 AS Interface Components IP67 2 1 1 6 Schematic View AUX AUX AUX AUX 1 4 2 3 5 1 4 2 3 5 IR FE FE AUX AUX ASI FID FAULT NTERFACE OUT1 3 OUT2 4 OUT1 OUT1 OUT3 OUT3 OUT OUT OUT2 OUT2 OUT OUT4 O...

Страница 12: ...Current carrying capacity per module max 8 A External voltage supply AUX acc to PELV Rated voltage 24 V 15 20 Connection system socket M12 x 1 5 pole AS Interface Operating voltage AS I 26 5 V 31 6 V...

Страница 13: ...o IEC 60068 2 27 EMC Immunity to interference CE acc to EN 61000 6 2 EMC Emission of interference CE acc to EN 61000 6 3 Approvals AS Interface Association Specification V3 0 ZU No 72601 CULUS UL508 C...

Страница 14: ...S Interface Module 4OUT 24V 2A Single Technical Data WAGO I O SYSTEM 751 AS Interface Components IP67 Tab 2 1 1 3 Technical Data Dimensions 73 39 33 ASI AUX 54 94 32 24 ASI AUX 4 5 Fig 2 1 1 5 Dimensi...

Страница 15: ...n the cutouts that are marked for this purpose Make sure that the cables engage behind the locking latch For modules with unused AUX socket insert the enclosed blanking cap to seal the cable entry 3 F...

Страница 16: ...ification may lead to malfunctions or restrictions Please note the AS interface master manual and the manual for the start up tool WAGO I O CHECK 2 759 302 for start up and diagnosis of the AS interfa...

Страница 17: ...751 4001 AS Interface Module 4OUT 24V 2A Single 17 Start up and diagnosis WAGO I O SYSTEM 751 AS Interface Components IP67...

Страница 18: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: