To set a Modbus Address for the industrial managed switch, choose a number
from 1 to 247 and enter it in the Modbus Address field. Click
[Submit]
button to
configure it. To enable the Modbus protocol on the industrial managed switch,
check the box behind the Modbus Enable and set a Modbus Port number by
choosing a number from 1 to 65535 and enter that number in the Modbus Port
field. Click
[Submit]
button to set the Modbus TCP. Table “WBM “Diagnostics”
Page – “Modbus TCP” Tab” summarizes the descriptions of the Modbus TCP’s
parameters.
Please refer to Appendix 0 for the Modbus Memory mapping.
Table 28: WBM “Diagnostics” Page – “Modbus TCP” Tab
Parameters
Factory Default Description
Modbus
Address
1
Enter a number from 1 to 247 to set the Modbus Address of
the industrial managed switch.
Modbus Enable Uncheck
Enable the Modbus protocol on the industrial managed switch
by checking the Modbus Enable box.
Modbus Port
502
Enter a number from 1 to 65535 to set the Modbus service port
number for the industrial managed switch.