751-5201 [AS-Interface Module 4IN/4OUT 24V/2A Single] 

 

 

 Schematic 

Diagram 

 

 

  

WAGO-I/O-SYSTEM 

751 

 

 

AS-Interface Components IP67 

2.1.1.6 Schematic Diagram 

AUX +

AUX -
AUX +

AUX -

Sensor

-

1

4

2

3

5

1

4

2

3

5

1

4

2

3

5

1

4

2

3

5

IR

FE

FE

FE

FE

AUX +

AUX -

ASI

FID/FAULT

IN+

IN1

IN2

IN1

NTERFACE

OUT1/3

OUT2/4

IN+

IN3

IN4

IN3

IN+

IN2

IN2

IN+

IN4

IN4

OUT1

OUT1

OUT3

OUT3

IN -

IN -

IN -

IN -

OUT - OUT -

OUT2

OUT2

OUT -

OUT4

OUT4

OUT -

AS-i -

AS-i +

ASI

AUX

IN1/3

IN2/4

751-5201

for 3-conductor sensors

Load

 

Fig. 2.1.1-5: Schematic Diagram 

gq52011e 

Содержание 751-5201

Страница 1: ...AS Interface Components IP67 AS Interface Module 4IN 4OUT 24V 2A Single 751 5201 Manual Version 1 1 0...

Страница 2: ...hone 49 0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can...

Страница 3: ...6 1 3 Number Notation 6 1 4 Safety Notes 7 1 5 Scope 7 2 AS Interface Components 8 2 1 AS Interface Module IP67 8 2 1 1 751 5201 AS Interface Module 4IN 4OUT 24V 2A Single 8 2 1 1 1 View 8 2 1 1 2 Des...

Страница 4: ...1 3 Actuator Connectors gqxxx02x 9 Fig 2 1 1 4 Display Elements gq52012x 11 Fig 2 1 1 5 Schematic Diagram gq52011e 12 Fig 2 1 1 6 Characteristic Input Curve gqxxx15e 15 Fig 2 1 1 7 Dimensions gqxxx09...

Страница 5: ...ther manufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this...

Страница 6: ...oth operation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for e...

Страница 7: ...t environment then additional measures are to be taken handling of the components only with clean tools and materials Attention Cleaning of soiled contacts may only be done with ethyl alcohol and leat...

Страница 8: ...1 5201 is an economical solution for a fieldbus independent and flexible connection of actuators and sensors from the field and the control cabinet The module is in accordance with AS Interface specif...

Страница 9: ...1 1 Sensor and Actuator Connectors Sensor Connectors Connector Pin Function IN 1 3 IN 2 4 1 Sensor supply L IN 1 3 2 Sensor signal from IN 2 4 Pin 4 IN 1 3 IN 2 4 3 Sensor supply L IN 1 3 IN 2 4 4 Sen...

Страница 10: ...ed sensor or actuator connections must be sealed with protective caps 2 1 1 3 3 Programming Connector The PGM connection is the programming connector It is a plug for a DC socket which is compatible w...

Страница 11: ...Status DO2 on Output 2 set off Output 3 reset OUT 3 yellow Status DO3 on Output 3 set off Output 4 reset OUT 4 yellow Status DO4 on Output 4 set off OK on Configuration error FID FAULT red Error blin...

Страница 12: ...AUX AUX AUX Sensor Sensor 1 4 2 3 5 1 4 2 3 5 1 4 2 3 5 1 4 2 3 5 IR FE FE FE FE AUX AUX ASI FID FAULT IN IN1 IN2 IN1 NTERFACE OUT1 3 OUT2 4 IN IN3 IN4 IN3 IN IN2 IN2 IN IN4 IN4 OUT1 OUT1 OUT3 OUT3 IN...

Страница 13: ...EC 61131 type 1 active 7 mA current sink type 2 Signal voltage 0 5 V Signal voltage 1 11 V Connection system Socket M12 x 1 5 pole Outputs Number of outputs 4 Output types Electronic outputs PNP Isola...

Страница 14: ...of data bits D0 D1 D2 D3 bidirectional I 1 O 1 bidirectional I 2 O 2 bidirectional I 3 O 3 bidirectional I 4 O 4 Connection system AS Interface cable contacted via piercing technology General Technic...

Страница 15: ...756 9204 040 000 M12 plug straight 5 pole screw clamp connection 756 9201 050 000 M12 plug right angle 5 pole screw clamp connection 756 9204 050 000 Fitted cables series 756 see catalog or www wago...

Страница 16: ...terface Module 4IN 4OUT 24V 2A Single Technical Data WAGO I O SYSTEM 751 AS Interface Components IP67 Tab 2 1 1 3 Technical Data Dimensions 39 33 73 107 AUX ASI 152 54 32 24 ASI AUX 4 5 Fig 2 1 1 7 Di...

Страница 17: ...in the cutouts that are marked for this purpose Make sure that the cables engage behind the locking latch For modules with unused AUX socket insert the enclosed blanking cap to seal the cable entry 3...

Страница 18: ...ecification may lead to malfunctions or restrictions Please note the AS interface master manual and the manual for the start up tool WAGO I O CHECK 2 759 302 for start up and diagnosis of the AS inter...

Страница 19: ...751 5201 AS Interface Module 4IN 4OUT 24V 2A Single 19 Start up and diagnosis WAGO I O SYSTEM 751 AS Interface Components IP67...

Страница 20: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: