WAGO I/O System 750
List of Figures 11
750-940 EnOcean RS-485 Gateway; 868 MHz
Manual
Version 1.3.0, valid from FW/HW Version 01/01
Pos: 16.11 /Alle Serien (Allgemeine Module)/Überschriften/Ebene 2/Sicherheitshinweise - Überschrift 2 @ 6\mod_1260180299987_21.docx @ 46724 @ 2 @ 1
2.2
Safety Advice (Precautions)
Pos: 16.12 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Einleitung Sicherheitshinweise Hardware @ 6\mod_1260180170493_21.docx @ 46720 @ @ 1
For installing and operating purposes of the relevant device to your system the
following safety precautions shall be observed:
Pos: 16.13 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Nicht an Geräten unter Spannung arbeiten! @ 6\mod_1260180365327_21.docx @ 46727 @ @ 1
Do not work on devices while energized!
All power sources to the device shall be switched off prior to performing any
installation, repair or maintenance work.
Pos: 16.14 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Trennvorrichtung und Überstromschutz @ 33\mod_1543915978439_21.docx @ 512267 @ @ 1
Ensure disconnect and overcurrent protection!
The device is intended for installation in automation technology systems.
Disconnect protection is not integrated. Connected systems must be protected by
a fuse.
Provide suitable disconnect and overcurrent protection on the system side!
Pos: 16.15 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Unfallverhütungsvorschriften beachten! @ 6\mod_1260180657000_21.docx @ 46735 @ @ 1
Pos: 16.16 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Nur SELV-Spannungsquelle verwenden! @ 23\mod_1439450789038_21.docx @ 188668 @ @ 1
Use SELV power source only!
The device must only be powered from a SELV (Safety Extra Low Voltage)
power source complying with the limited power source (LPS) requirements per
DIN EN 60950-1.
Pos: 16.17 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Auf normgerechten Anschluss achten! @ 6\mod_1260180753479_21.docx @ 46739 @ @ 1
Ensure a standard connection!
To minimize any hazardous situations resulting in personal injury or to avoid
failures in your system, the data and power supply lines shall be installed
according to standards, with careful attention given to ensuring the correct
terminal assignment. Always adhere to the EMC directives applicable to your
application.
Pos: 16.18 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Achtung/Achtung: Defekte oder beschädigte Geräte austauschen! @ 6\mod_1260180857358_21.docx @ 46743 @ @ 1
Replace defective or damaged devices!
Replace defective or damaged device/module (e.g., in the event of deformed
contacts).
Pos: 16.19 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Achtung/Achtung: Geräte vor kriechenden Stoffen schützen! @ 37\mod_1597332188822_21.docx @ 588074 @ @ 1