OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2333538
5.4.2
PRESSURE REGULATOR DEVICE
1 Pressure regulator
2 Ball valve
3 Pressure gauge
4 Compressed air inlet
5 AirCoat regulator (option)
Positions of the ball valve
1
Closed: operating pressure in the air motor will
be relieved (control pressure is still present).
2
Closed: the air motor can still be under pressure
3
Open: working position
Pneumatic pump
Puma 28-40 Airless
5.4.3
HIGH-PRESSURE FILTER (OPTION)
5.4.3.1
HIGH-PRESSURE FILTER (OPTION)
To ensure problem-free operation it is recommended that
a WAGNER high pressure fi lter be used. These have been
developed especially for WAGNER pneumatic pumps. The
fi lter inserts can be exchanged depending on the material to
be used. The respective high pressure fi lters and their inserts
for the device can be found in the accessories list.
1
Fluid section
connection
2
Material outlet
3
Return line
Closed
Open
Preferred fi lter
installation
position
Open
(Return line)
Closed
(Spraying)
up to 270 bar; 3,916 psi
up to 530 bar; 7,687 psi
Pneumatic pump
Puma 28-40 AirCoat
So that the complete pressure relief of the pump can be performed
(see Chapter 7.2.2), a high-pressure fi lter with a return line or a
relief combination, is mandatory.