E / 9
ENGLISH
4.9 Scheduled maintenance table
MAINTENANCE OPERATION
Every
Every
Every
Every
day
week
6 months
2 years
Checking the oil level
X
Draining the condensation
X
Routine cleaning of compressor
X
Cleaning the intake filter
X
X
Replacing the oil
X
General cleaning of compressor
X
Check belt tension
X
Check/cleaning valves
X
4.10 Recommended oils
(suitable for room temperature ranging from +5°C and + 25°C)
Room temperature below +5°C ISO 68
Room temperature above +25°C ISO 150
SHELL Rimula D Extra 15W-40
API CM-8X
AGIP Dicrea 100
BP Energol CS100
CASTROL Aircol PD100
ESSO Exxc Olub H150
IP Calatia Oil ISO 100
MOBIL Rarus 427
TOTAL Dacnis P100
FUCHX Renolin 104L VG100
4.MAINTENANCE
5.TECHNICAL DATA
ELECTRICAL
Power
Voltage
Absorption
Cable
Sectioning
POWERED
cross section
switch
HP
Volt/Ph.
A
mm²
A
1.5
230/1
7.5
-
-
2
230/1
9
-
-
323
0/1
12.5
-
-
4
230/1
17
-
-
4
400/37
1
20
EXPLOSION
Power FuelFuel
type
Fuel
Engine
ENGINE
quantity
consumption oil q.ty
HP
lt.
lt/h
lt.
3.5
1.9
Lead free gasoline (min.77 octane)
1
0.6
5
3
.8
Lead free gasoline (min.77 octane)
1.2
0.6
9
6
Lead free gasoline (min.88 octane)
2.31.4
11
7.1
Lead free gasoline (min.88 octane)
2.8
1.5