11. Correction of Malfunctions
Problem
Cause
Remedy
A.
Not enough
material is
coming out
•
The material limiter is set to the
upper position
•
Container empty
•
Trigger is not pressed very often.
•
Container not inserted properly
•
Remains of material around the
container valve
•
Container valve blocked
•
Material too thick
➞
Push the limiter down
➞
Refill container
➞
Press the trigger more
frequently/for longer periods
➞
Insert properly
➞
Clean (see fig. 13, a)
➞
Clean (see fig. 16 and 17)
➞
Dilute according to
manufacturer's instructions
B.
Too much
material is
coming out
•
Material limiter is set to the lower
position
•
Trigger is pressed too frequently.
➞
Push the limiter up
➞
Press trigger less frequently/
for shorter periods
C.
No material
comes out
at all
•
Tube loose in container or
blocked
•
Not enough material in the
container
➞
Secure tube or clean (see fig.
15)
➞
Refill container
D.
Application
of material
does not
cover surface
(stripy)
•
Not enough material on the
application pad
•
Application pad and/or groove
brush damaged
➞
See solutions suggested in
section A
➞
Replace
E.
Renuvo leaks
•
Container not inserted properly
•
Application pad not mounted
correctly
•
Remains of material around the
container valve
➞
Insert properly
➞
Mount application pad
securely
➞
Clean (see fig. 13, a)