4.1 Control unit
1 Master switch 0 –1
2 Indicator lamp
3 Feed rate regulator 0 –10
4 Changeover switch
5 Mains cable
6 Connection for remote control
The mortar spraying machine can be switched on using
the master switch (1, fig. 3).
The indicator lamp (2) shows that the machine is ready
for operation.
The feed rate can be continuously adjusted by means of
the feed rate switch (3).
4.1.1 Symbols on the changeover switch
(fig. 4)
1 Releasing the pressure or removing the pump jacket.
Pump runs in reverse direction.
2 "0" drive is switched off.
3 "AUTO" remote control using the spray lance.
4 Spraying or pulling on the pump jacket.
Pump runs in the forwards direction.
4.2 Drive
If overloading occurs then the mortar spraying machine
switches off. Turn master switch (1, fig. 3) and change-
over switch (4, fig. 3) to "0". Wait at least 10 seconds
and then turn the mortar spraying machine back on.
4.3 Receptacle
(fig. 5)
1 receptacle made of high-grade steel with grating.
Contents: 60 liter
29
g
2
5
3
4
1
6
AUTO.
O
1
4
2
3