Operating manual Powder Cup Gun PEM-X1 CG
8 Cleaning and Maintenance
30
Order number 2326960 | Edition 10/2022
8 CLEANING AND MAINTENANCE
8.1 CLEANING
8.1.1 Cleaning Personnel
Cleaning work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.
The following hazards may arise during cleaning work:
– health hazard from inhaling powder lacquer,
– use of unsuitable cleaning tools and aids.
8.1.2 Cleaning Procedures
The cleaning intervals should be adapted by the operator depending on the level of use and
if necessary the level of soiling.
If in doubt, we recommend contacting WAGNER's specialist personnel.
8.1.2.1 Cleaning Process
1. End the coating procedure.
2. Press [Flush] button on control unit.
3. Let the cleaning function run until the powder cup is completely empty.
4. Push the [Flush] button on the control unit, in order to switch off the cleaning function.
5. Remove the powder cup from the cup gun.
6. Clean the powder cup and powder cup's cover with compressed air.
7. Unscrew the union nut with nozzle system from the cup gun.
8. Press the nozzle system out of the union nut and clean all parts thoroughly.
9. Thoroughly blow out the cup gun from the rear, on the cup gun fitting, and from the
front.
10. Assemble the nozzle system and, with the union nut, attach it to the cup gun.
11. Attach the powder cup, fill it with powder and put on the cover.
12. Continue the coating process.
8.2 MAINTENANCE
8.2.1 Maintenance Personnel
Maintenance work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.
The following hazards may arise during maintenance work:
– health hazard from inhaling powder lacquer,
– use of unsuitable tools and aids.
A skilled person must ensure that the device is checked for being in a reliable state after
maintenance work is completed.