Maintenance and cleaning
20
0390882
-
PEA-C4-HiCoat FM
01 / 2008
Hint
For inserting the protective wedge the same
wedge tool
will be used.
1
Wedge
tool
2
Protective
wedge
3
Electrode holder (cut open view)
Proceed as described below:
•
Guide the protective wedge
2
into the
wedge tool
1
.
•
Insert both parts in the opening on the
electrode holder
3
to the stop.
•
If it is not possible to push the wedge tool in
as far as the mark
X
, rotate the wedge tool
a little until it can be pushed into the mark.
The
mark
X
must be flush with the end
Y
of
the electrode holder.
•
The protective wedge is now correctly
assembled and the wedge tool can be
pulled back out of the electrode holder.
The protective wedge remains inserted in
the electrode holder.