Maintenance and cleaning
01 / 2008
0390882
-
PEA-C4-HiCoat FM
17
0401_.doc
G
J
H
F
E
D
Peac4_0004
•
Switch off the plant and/or the high voltage generator.
•
Disconnect the electrical cable
E
from the spray gun
D
.
•
Disconnect the hoses for powder feed
G
and atomizing air
F
from the spray gun
D
.
•
Undo the locking nuts
H
and disconnect the spray gun
D
from the support
J
.
•
Replace the spray gun with a new gun and fit this in the reverse order of removal.