2.3
SAFETY INSTRUCTIONS
Observe the safety instructions in Chapter 4 and in Chapter 8.1.2 of the corresponding
operating manual.
Before repair work
- Flush and clean the system. Chapter 8.1.3 in the operating manual.
After repair work
- Carry out safety checks in accordance with Chapter 8.2.3. of the operating manual.
- Commission the system and check for leaks as described in Chapter 6.8 of the
operating manual.
- Function test in accordance with Chapter 3.
In accordance with the guideline for liquid ejection devices (ZH 1/406 and BGR 500
Part 2 Chapter 2.29 and Chapter 2.36):
- The liquid ejection devices should be checked by an expert (e.g. Wagner service
technician) for their safe working conditions as required and at least every
12 months.
- For shut down devices, the examination can be suspended until the next start-up.
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the Chapter
"Spare parts" and that are assigned to the unit.
Before all work on the device and in the event of work
interruptions:
- Switch off the energy and compressed air supply.
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
Observe the operating manual and service manuals at all times
when carrying out work.