Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
Order number 2354913 | Edition 10/2022
39
Recipes 5 – 50 can be indirectly selected and saved. First press the [Additional recipes] push
button (25). The yellow [Additional recipes] LED (26) then lights up and the LED display (19)
indicates the current recipe number. The required recipe can be set by turning the universal
control dial (24). In the following example, the values in recipe no. 10 are to be modified and
saved.
1. Select recipe no. 10.
2. Set the desired values in the recipe, see Chapter Setting the Total Air Volume [
and the following chapters.
3. Instead of showing the current recipe number, the LED display (19) now shows the
modified value.
4. To save the changes, hold down the [Additional recipes] button (25) until the previous
recipe number flashes in the LED display (19).
5. To save the values, there are two options:
4
To save the recipe to the recipe number currently displayed, hold the [Additional
recipes] button (25) down for another 2 seconds until the yellow [Additional
recipes] LED (26) flashes quickly. The modified values are then saved to the original
recipe.
4
To save the changes to another recipe number, use universal control dial (24) to set
the desired recipe number - this is now displayed flashing. To save the values, press
and hold down the [Additional recipes] button (25) for 2 seconds until the yellow
[Additional recipes] LED (26) flashes quickly. The changes are thereby saved to the
set recipe number.
7.6 SETTING AND CHANGING COATING PARAMETERS
7.6.1 Setting the Total Air Volume
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_05019
22
20
1. Press [Total air volume] push button (20) to adjust the total air volume. Yellow LED (22)
indicates that the total air volume is selected.