44
AquaCoat GM 5000EACW
AquaCoat
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R2
R1
Zerstäuberluft
Atomizing air
Mat. Druckregler
Mat. pressure reg.
Pumpe
Pump
POWER
0
1
21
15
22
1
10
9
11
3
B_03371
AquaCoat
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R2
R1
Zerstäuberluft
Atomizing air
Mat. Druckregler
Mat. pressure reg.
Pumpe
Pump
POWER
0
1
AquaCoat
1
B_03520
OPERATING MANUAL
EDITION 04/2012
PART NO. DOC2321362
5.4
WORKS
1. Turn on the control unitVM 5000W. Set main switch (1) to position 1. During the
start-up phase, the device automatically performs an internal function test and then
automatically switches to recipe 1 (15).
2. Set the desired recipe.
3. Set operating pressure of approx. 8 MPa; 80 bar; 1160 psi for the pump regulator (9).
Note:
In the case of material pressure generators with attached control unit, use the regulator
on the device.
4. Release the spray gun.
5. Spray on a test object (pull trigger).
Note:
If the trigger guard is now actuated, the high voltage is switched on and both displays
(21) and (22) change from point to bar display, i.e. the actual value of the high voltage
(21) and the actual value of the spray current (22) are displayed.
6. The high voltage can be switched on and off with the pushbutton (3).
7. Now open AirCoat air (11), approx. 0.01-0.25 MPa; 1-2.5 bar; 14,5-36 psi, and adjust for
the optimal atomization.
5.4.1
PREPARATION FOR SPRAYING WITH FLAT-JET NOZZLE
Содержание AquaCoat AirCoat GM 5000EACW