![WAGNER AquaCoat AirCoat GM 5000EACW Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/wagner/aquacoat-aircoat-gm-5000eacw/aquacoat-aircoat-gm-5000eacw_operating-manual_867918035.webp)
35
AquaCoat GM 5000EACW
B_03525
R
max.
< 1 M
Ω
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R2
R1
Zerstäuberluft
Atomizing air
Mat. Druckregler
Mat. pressure reg.
Pumpe
Pump
POWER
0
1
OPERATING MANUAL
EDITION 04/2012
PART NO. DOC2321362
Perfect earthing of all system components (workpieces, conveyor, paint supply system,
control unit, spray booth or spraying stand, see illustration) is a prerequisite for optimum
coating effi ciency and safety.
WARNING
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
Earth all unit components.
Earth the workpieces being painted.
SIHI_0003_GB
Earthing schema (example)
Conveyor
Spraying stand
Floor, derivable
Object
System earth
5.1.4
EARTHING
System earth
The imperfect earthing of a work piece will result in:
●
Very poor wrap-around.
●
Uneven coating thickness.
●
Back spraying to the spray gun, i.e. contamination.
The prerequisites for perfect earthing and coating are:
●
Clean work piece suspension.
●
Earthing of spray booth, conveyor system and suspension on the building side in
accordance with the operating instruction or the manufacturer’s information.
●
Earthing of all conductive parts within the working area.
●
The earthing resistance of the work piece may not exceed 1 M
(Mega Ohm).
Resistance to earth measured at 500 V or 1000 V.
●
Connect the AquaCoat cabinet to the system earth.
●
The work shoes and if uses the gloves must be derivable.
Содержание AquaCoat AirCoat GM 5000EACW
Страница 2: ......
Страница 38: ...38 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Страница 92: ...92 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Страница 101: ...101 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Страница 111: ......