VM 500
VERSION 09/2018
ORDER NUMBER DOC 2318724
17
5.4
INCLUDED ITEMS
Order no. Designation
1
2310478
VM 500 control unit
5.4.1 STANDARD EQUIPMENT
Order no.
Designation
1
241270
Mains cable with Stak200; 3 m; 9.8 ft
1
130215
Grounding cable 10 m; 32.8 ft
2
9951117
Slow-acting fuse, 1.0 AT
1
2310487
Declaration of Conformity
1
2310485
VM 500 operating manual, German
1
see Chapter
Operating manual in local language
For special versions the delivery note applies.
5.5
DATA
5.6
TECHNICAL DATA
Description
Values
Input voltage
115 VAC - 230 VAC, 50 Hz / 60 Hz
Input power
max. 40 W
Input current
max. 0.5 A
Output voltage
max. 20 Vpp
Output current
max. 1.0 A AC
High-voltage limitation
80 kV DC
Spray current limitation
100 µA DC
Polarity
for negative high-voltage generators
Protection class
IP 54 *
Weight (without cables)
2.3 kg; 5.07 lb
Operating temperature range
0-40 °C; 32-104 °F
*
Splash water protection is only guaranteed when the spray gun cable socket is screwed to the device plug and
the mains cable socket is fixed to the control unit plug with the safety clip.
5.7
DIMENSIONS
Measurement mm
inch
A
B
C
B_03417
VM 500
A
230
9.06
B
180
7.09
C
120
4.72