![Wagner & Co SECUSOL Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/wagner-and-co/secusol/secusol_technical-information-installation-instructions_868282002.webp)
2
EN-USA_SECUSOL_TI-MA-111013-1121R800
1 Technical Information
1.1 Technical Data
Table 1 Technical Data
Features
SECUSOL
250-1
SECUSOL
250-2
SECUSOL
350-2
Solar collectors
Type
EURO C20 AR-M
EURO L42 or EURO C20 AR-M
Gross area / aperture area sq ft (m²)
EURO C20 AR-M
28.1 sq ft (2.61 m²) /
25.7 sq ft (2.39 m²)
EURO L42
24.2 sq ft (2.25 m²) /
21.6 sq ft (2.01 m²
Collector racking
On roof or free standing
Orientation of collector
Horizontal installation only (pitch of 10° – 85°),
max. permitted diversion from horizontal orientation: 2°
No. of collectors
1
2 (cannot be extended)
Solar circuit
Collector circuit material (on site)
Cu 12 mm, order as needed from Wagner Solar, see material requirements in table 8
Insulation material (accessory)
see material requirements in table 8
Length of solar circuit
(sum of flow and return legs)
1
Minimum 16.4 ft (5 m) / maximum 98.4 ft (30 m)
Maximum operating pressure
87 psi (6 bar)
Installation height
2)
Minimum 3.3 ft (1 m), from the bottom of the tank to the bottom of the collector
Maximum 28 ft (approx. 8.5 m), from the bottom of the tank to the top of the collector
Minimum temperature
Frost resistant up to 1.4 °F (-17 °C), if correctly filled
2)
Heat transfer fluid in
collector loop
Water/propylene glycol mix only with 33 % glycol
1)
,
filling capacity: 1.9 to 1.95 Gal (7.2-7.4 liters)
Solar controller
Name
SUNGO US plus
Pump control
Speed controlled
Overheat protection
180 °F temperature limitation for the tank
Storage
Nominal content
66 Gal (250 l)
92.2 Gal (350 l)
Stand by heating volume
approx. 32 Gal (120 l)
approx. 42 Gal (160 l)
Total height (including insulation)
62.83 in (1596 mm)
72.64 in (1845 mm)
Diameter (including insulation)
29.53 in (750 mm)
Permissible operation pressure /
Permissible operating temperature
145 psi / 203 °F (10 bar / 95 °C)
Corrosion protection
of the storage cylinder
Enamel coating according to DIN 4753 T3
Cathodic corrosion protection
Mg sacrificial anode acc. to DIN 4753 T6
Cold/hot water connections
1" NPT (M)
Sensor connection
Clip in lower tank area
Solar heat exchanger
approx. 12.39 sq ft (1.15 m²)
Backup heating coil
none / approx. 6.0 sq ft (0.65 m²), depending on type
approx. 8.61 sq ft (0.8) m²
Socket for electrical immersion heater,
Position:
1" NPSM (F)
Heat insulation
(PU foam, polystyrene jacket)
Cylinder and lid approx. 2.25 in (75 mm)
Base 1.57 in (40 mm)
Weight
285.5 lb (129.5 kg)
307.5 lb (139.5 kg)
1) See Figure 28 page31.
2) Lower edge of storage cylinder to lower edge of collector (Figure 28 page31).
3) In order to achieve higher frost protection, the glycol content needs to be increased to over 33 %. However, this results in increased
pressure drop and hence a reduced maximum installation height and length of solar circuit. Please also observe the technical
information of the solar liquid. If required feel free to contact our technical support.