WAFER GSM-RELAY REMOTE CONTROL UNIT 

http://www.waferlife.com 

OUT6-OFFWSD6OFF 

#PWD123456#OUT-REPLY-TEXT?     (only for PC command)

 

OUT1-ON-REPLY-TEXT:WSD1ON OK 
OUT1-OFF-REPLY-TEXT:WSD1OFF OK 
OUT2-ON-REPLY-TEXT:WSD2ON OK 
OUT2-OFF-REPLY-TEXT:WSD2OFF OK 
OUT3-ON-REPLY-TEXT:WSD3ON OK 
OUT3-OFF-REPLY-TEXT:WSD3OFF OK 
OUT4-ON-REPLY-TEXT:WSD4ON OK 
OUT4-OFF-REPLY-TEXT:WSD4OFF OK 
OUT5-ON-REPLY-TEXT:WSD5ON OK 
OUT5-OFF-REPLY-TEXT:WSD5OFF OK 
OUT6-ON-REPLY-TEXT:WSD6ON OK 
OUT6-OFF-REPLY-TEXT:WSD6OFF OK 

 
PWD123456#RLY-TEXT?      (only for PC command) 

RLY1-TEXT:WSDRLY1 
RLY1-REPLY-TEXT:WSDRLY1 OK 
RLY2-TEXT:WSDRLY2 
RLY2-REPLY-TEXT:WSDRLY2 OK 
RLY3-TEXT:WSDRLY3 
RLY3-REPLY-TEXT:WSDRLY3 OK 
RLY4-TEXT:WSDRLY4 
RLY4-REPLY-TEXT:WSDRLY4 OK 
RLY5-TEXT:WSDRLY5 
RLY5-REPLY-TEXT:WSDRLY5 OK 
RLY6-TEXT:WSDRLY6 
RLY6-REPLY-TEXT:WSDRLY6 OK 
 

Data Log Check (Only for PC Connnecting , don’t send the SMS command for this) 

With this command,we can check the inside config and control Log information 

#PWD123456#LOG=ALL? 

Reply would be as following data: 
……… 
LOGS015:201501072143:18017370819:PHONE 
LOGS016:201501072143:18017370819:PHONE 
LOGS017:201501072141:18017370819:PHONE 
LOGS018:2015018613564121668:WSDRLY2=13 
LOGS019:2015018613564121668:WSDRLY6=6 
LOGS020:2015018613564121668:RLY3=8

………. 

………. 

#ALARM Alarm setup 

In GSM-RELAY6, that Alarm01 is very important position,not only act as a alarm number,but also working 

Содержание GSM-RELAY6

Страница 1: ...WAFER GSM RELAY REMOTE CONTROL UNIT http www waferlife com GSM RELAY6 MANUAL V1 1 From 2018 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Страница 2: ...has 6 Relay switch output and 6 alarm input port CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM RELAY6 6 channels 230V 10A 50Hz relay contacts 6 alarm input port for separate switch type sensor input...

Страница 3: ...rchased separately with 3m cable You should then insert the SIM Card of the operator you want to use with the right direction according to the following pictures Note You must remove the PIN request f...

Страница 4: ...e password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be...

Страница 5: ...program 3446665555 If your number appears as 85261143815 you should not program the country code 852 If your number has only 17 digits or less it is not a problem The important thing is that you don...

Страница 6: ...d to Second or Minute PWD123456 TIMER DELAY AT MILLISECOND PWD123456 TIMER DELAY AT SECOND PWD123456 TIMER DELAY AT MINUTE MODE Relay Operation Mode SETUP PC PHONE Only for NO 1 Relay PWD123456 MODE0...

Страница 7: ...will receiver the following message when the relay switches off OUT2 Timer OFF OK Note Relay1 cann t be controlled by the RLY command if you want to control the Relay1 at a temporary latching timer y...

Страница 8: ...user only need to send the sms open1 and when received this sms OUT1 will be ON PWD123456 OUT1 ON TEXT XXXX PWD123456 OUT1 OFF TEXT XXXX PWD123456 OUT1 ON REPLY TEXT XXXX PWD123456 OUT1 OFF REPLY TEXT...

Страница 9: ...RLY2 REPLY TEXT WSDRLY2 OK RLY3 TEXT WSDRLY3 RLY3 REPLY TEXT WSDRLY3 OK RLY4 TEXT WSDRLY4 RLY4 REPLY TEXT WSDRLY4 OK RLY5 TEXT WSDRLY5 RLY5 REPLY TEXT WSDRLY5 OK RLY6 TEXT WSDRLY6 RLY6 REPLY TEXT WSD...

Страница 10: ...00 4 Config the SMS TEXT PC PWD123456 UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX Acknowledge UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX OKAY When the Alarm input is triggered the...

Страница 11: ...y to move to another place to test If still cann t registered to the GSM net try to contact wafer to get the technical support When LED D6 is flashing slowly try to call the SIM card the calling statu...

Страница 12: ...ach relay output has NO and COM contacts Note Power supply for the each load mustn t exceed 30VDC 10A or 230VAC 10A Warning GSM RELAY6 device only work as a high power switch don t power the LOAD dire...