#REPLY SMS reply enable or disable for relay output control command

 

This command is used to save the cost for SMS reply when no need the SMS reply back 

#PWD123456#REPLY=ON or #PWD123456#REPLY=OFF

 

When REPLY=OFF,then any relay output control text command would no confirmed SMS reply 
from controller,including the OUT, RLY and the Customized Text Command 
 

#WHL White List

This is the command that you will use most. it is used to add or remove numbers that are enabled 
to control the relay sets into the White List. You can add up to 200 numbers in the list. Every 
position must be indicated in the command and we advise you to keep a list written somewhere to 
know which numbers are in and in which position. 

• To add a number with SMS, the syntax of the command is the following: 

#PWD123456#WHL01=61143815 

Acknowledge 

would be : 

WHL01 SET TO 61143815 OK

 

Where 01 is the position in the list and 61143815 is the number enabled. 
Please note that it is possible to program up to a maximum of 18 digits for a number. If it has 
more digits you should use the rightmost ones. For example, if your number is 33446665555 you 
should program 3446665555. If your number appears as +85261143815 you should not program 
the country code (+852). If your number has only 17 digits or less, it is not a problem. The 
important thing is that you don't exceed 18 digits. 

• To add a new number,you also can use the fast teaching button

   

(only from WHL01 to WHL10) 
Press the button KEY1 for around 2 to 3 second and then the LED D1 would be lighting,and then 
you can use the phone to call the device number and then device would reject the calling and the 
LED D1 would flash one or two times,then the number would be saved. If you need to continue to 
program,then just use another phone to call the device. If you don’t need to program more ,then 
just press the KEY1 button again to QUIT the teaching process,then the LED D1 would be OFF. 
Then you can use the numbers just programmed into the device to control the device. 

(Fast Button program only support the program from WHL01 to WHL10,if it is full,then after 
you press the teach button,the LED would flash sometimes,and Quit the process automatically) 

 
• To check which is the number in a place of the list: 

#PWD123456#WHL01? 

Acknowledge 

: WHL01 IS 61143815 OK 

• To erase a number: 

#PWD123456#WHL01=0000000 

(or you can write over it another number you wish to add) 
Acknowledge : 

WHL01 SET TO 00000000 

List All numbers in the List 

#PWD123456#WHL=ALL?  

(

PC)

 

Acknowledge 

:  

WHL01 IS XXX 

WHL08 IS XXX 

…… 

Содержание GSM-RELAY6

Страница 1: ...WAFER GSM RELAY REMOTE CONTROL UNIT http www waferlife com GSM RELAY6 MANUAL V1 1 From 2018 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Страница 2: ...has 6 Relay switch output and 6 alarm input port CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM RELAY6 6 channels 230V 10A 50Hz relay contacts 6 alarm input port for separate switch type sensor input...

Страница 3: ...rchased separately with 3m cable You should then insert the SIM Card of the operator you want to use with the right direction according to the following pictures Note You must remove the PIN request f...

Страница 4: ...e password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be...

Страница 5: ...program 3446665555 If your number appears as 85261143815 you should not program the country code 852 If your number has only 17 digits or less it is not a problem The important thing is that you don...

Страница 6: ...d to Second or Minute PWD123456 TIMER DELAY AT MILLISECOND PWD123456 TIMER DELAY AT SECOND PWD123456 TIMER DELAY AT MINUTE MODE Relay Operation Mode SETUP PC PHONE Only for NO 1 Relay PWD123456 MODE0...

Страница 7: ...will receiver the following message when the relay switches off OUT2 Timer OFF OK Note Relay1 cann t be controlled by the RLY command if you want to control the Relay1 at a temporary latching timer y...

Страница 8: ...user only need to send the sms open1 and when received this sms OUT1 will be ON PWD123456 OUT1 ON TEXT XXXX PWD123456 OUT1 OFF TEXT XXXX PWD123456 OUT1 ON REPLY TEXT XXXX PWD123456 OUT1 OFF REPLY TEXT...

Страница 9: ...RLY2 REPLY TEXT WSDRLY2 OK RLY3 TEXT WSDRLY3 RLY3 REPLY TEXT WSDRLY3 OK RLY4 TEXT WSDRLY4 RLY4 REPLY TEXT WSDRLY4 OK RLY5 TEXT WSDRLY5 RLY5 REPLY TEXT WSDRLY5 OK RLY6 TEXT WSDRLY6 RLY6 REPLY TEXT WSD...

Страница 10: ...00 4 Config the SMS TEXT PC PWD123456 UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX Acknowledge UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX OKAY When the Alarm input is triggered the...

Страница 11: ...y to move to another place to test If still cann t registered to the GSM net try to contact wafer to get the technical support When LED D6 is flashing slowly try to call the SIM card the calling statu...

Страница 12: ...ach relay output has NO and COM contacts Note Power supply for the each load mustn t exceed 30VDC 10A or 230VAC 10A Warning GSM RELAY6 device only work as a high power switch don t power the LOAD dire...