WAFER GSM-RELAY REMOTE CONTROL UNIT
http://www.waferstar.com
About the power failure alarm:
(1) About the battery: Should use the 3.7V Polymer lion echargeable battery
(2) About the alert SMS: When the main power supply failure, will send the alert SMS to the WHL01 number.
Program software:
Please download from the product link:
http://www.waferstar.com/en/GSM-RELAY.html
On board Reset:
Press and hold the button for around 10 second,then the board would reseted,and the following
data would be reseted to:
Password:123456
,
From WHL01 to WHL10 would be cleared
ACM=OFF, REPLY=ON, MODE=MODE0, GOT=3S, Relay Output=0000000
Troubleshooting
No LED is on after power up
·
Check the power supply.
·
Check the wires is connected well.
GSM
LED D6
is not flash slowly
(GSM LED normally flash quickly when power off and when it connected to GSM net ,then
would flash around two seconds per time).
·
Check your ordered device if that is the proper GSM BAND to your country.
(Some country is QUAD BAND , some others is DUAL BAND, please check wafer website:
http://www.waferstar.com/en/gsm-frequencies-list.html
to check if that is proper)
·
Check the SIM card is properly inserted.
·
Check the PIN.(Normally don’t need to check, if SIM card can work with your mobile phone.)
·
Check the antenna connection is fitted well.
·
GSM Signal is not good and cann’t register to GSM,try to move to another place to test.
·
If still cann’t registered to the GSM net, try to contact wafer to get the technical support
·
When LED D6 is flashing slowly,try to call the SIM card,the calling status would be in busy.
MCU
LED D4
is not flash slowly
·
MCU is not working properly,Check the system power
No Relay working tone can be heard when phone calling the device
·
Check if your Control number is already setup into the device.
·
GSM-RELAY is not initialized properly upon start (approx. 10s after power up).
·
If the GOT timer is setup to a very short timer ( normally should be more than 500ms )
GSM-RELAY does not communicate with PC