http://www.waferstar.com 

 

#OUT Control the Relay Output on or off 

 

(PC$PHONE) 

#PWD123456#OUT1=ON or OFF 
#PWD123456#OUT2=ON or OFF  

(If has the second relay output on board) 

 

Config the RELAY Status when power Reset again 

#PWD123456#POWER-RESET=11 (1 means ON ,0 means OFF when power on) 

You will receive the following similar confirmation from the unit 

   

POWER-RESET OK

 

#PWD123456#POWER-SAVE 

You will receive the following similar confirmation from the unit 

   

POWER-SAVE OK

 

 

Customized output control command TEXT: 

  

(PC$PHONE) 

#REPLY SMS reply OFF or ON 
#PWD123456#REPLY=ON 

When setup to ON,then Device will reply the customized command after Relay is toggled 

#PWD123456#REPLY=OFF 

When setup to OFF,then Device will not reply the customized command after Relay is toggled 

(This command is used to save the cost for user) 

With these command you can customize the command to control your output.then would be easy 
for you to understand the command 

#PWD123456#OPEN1-TEXT#XXXX 
#PWD123456#CLOSE1-TEXT#XXXX 
#PWD123456#RLY-TEXT1#XXXX 

If have the second output reply,then use the following command to config the second output 

#PWD123456#OPEN2-TEXT#XXXX 
#PWD123456#CLOSE2-TEXT#XXXX 
#PWD123456#RLY-TEXT2#XXX 

Check the Customized command text: 

#PWD123456#OUT1-TEXT? 

Reply:

 

OPEN1-TEXT=OPEN1,CLOSE1-TEXT=CLOSE1,TRIG1-TEXT=XXXX 

#PWD123456#OUT2-TEXT? 

Reply:

 

OPEN2-TEXT=OPEN2,CLOSE2-TEXT=CLOSE2,TRIG2-TEXT=XXXX 

 

For example,you send the command:   

#PWD123456#OPEN1-TEXT#GATE1 OPEN 

Then you can use the simple SMS: GATE1 OPEN to switch on the output1 relay 

#PWD123456#CLOSE1-TEXT#GATE1 CLOSE 

Then you can use the simple SMS: GATE1 CLOSE to switch off the output1 relay 

#PWD123456#RLY-TEXT1#GATE1 DIAN 

Then you can use the simple SMS: GATE1 DIAN=5 to trigger the output1 relay for 5 second 
 

Содержание GSM-KEY-3G

Страница 1: ...WAFER GSM KEY REMOTE CONTROL UNIT http www waferstar com GSM KEY 3G MANUAL New version published from 2016 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Страница 2: ...st of numbers who are enabled to open the phone up to 2000 When the GSM KEY receives a call it will check to see if the calling number is in the list If it is in the list it will reject the call so th...

Страница 3: ...s Note You must remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually t...

Страница 4: ...L LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character Some complicated Instructions that cann t be programmed by the phone SMS That would need to use the PC software to p...

Страница 5: ...sword then reply would be Error New Password Please Check the input again WHL White List This is the command that you will use most it is used to add or remove numbers that are enabled to open the gat...

Страница 6: ...18 26 PHL001 number would operate from 8 32 to 18 26 from Mar 24th to Oct 12 Set how many times these numbers can operate QHL maximum number is 100 PWD123456 QHL001 13564121668 12 Acknowledge QHL003...

Страница 7: ...Acknowledge DELAY TIME IS 05000 MS ALARM Alarm setup In GSM KEY V2015 that Alarm01 is very important position not only act as a alarm number but also working as the REPORT phone number that means if y...

Страница 8: ...MS to Alarm01 number PWD123456 REPORT OFF No report for the device status change PWD123456 REPORT Check the REPORT setting status CSQ Check GSM signal quality PC PHONE This command is useful to see wh...

Страница 9: ...This command is used to save the cost for user With these command you can customize the command to control your output then would be easy for you to understand the command PWD123456 OPEN1 TEXT XXXX P...

Страница 10: ...r local language please contact wafer company COM Port parameters config interface and connect to the device Before program the device through the PC firstly you need to config the COM port paramters...

Страница 11: ...e that is to use the SMS to program the remote GSM KEY device So you need to input the Receive expired time and also need to input the GSM KEY device SIM card number into the unit phone number text bo...

Страница 12: ...REMOTE CONTROL UNIT http www waferstar com Phone Numbers Setting interface Before download the phone numbers you need to SET the index to red color then push the button Download All Phones Special Ph...

Страница 13: ...WAFER GSM KEY REMOTE CONTROL UNIT http www waferstar com Alarm Phone Numbers Setting Log Interface...

Страница 14: ...ed to update the clock Band selection Not available Relay Mode That is used to setup the working mode Relay Status That is used to test the device through ON or OFF the on board relay Alarm That is us...

Страница 15: ...t can be find in the computer device manager or not Our device has no relationship with the COM port can be find or not If you use the USB to RS232 adapter should check the drive is properly installed...

Страница 16: ...of WEIFU GSM Modules For further information and queries kindly contact Email wafer waferstar com Web www waferstar com Tel 0086 21 51870528 Also accessible via our online Service Skype wafer service...

Отзывы: