WAFE 350 Operation | 19
WAFE 350 OPERATION
WAFE 350
has been designed for your maximum comfort. After installation and initial setup of
operating values by
WAFE
technician (according to the construction project, see section
WAFE 350 Installation / Installation and handover
), the unit needs little to no attention.
Operation modes
INTELLIGENT
MODE
The unit analyses its surroundings and through optimal ventilation keeps the CO
2
levels as low
as possible.
Recommended for general use.
Requires manual activation and deactivation through my.wafe.eu.
In case CO
2
sensors are damaged unit will automatically switch to the forced
Weekly mode
.
WEEKLY MODE
The unit provides ventilation according to its factory settings (constantly except for workdays
from 8AM till 4PM) or according to its own time schedule set up at my.wafe.eu.
Alternative to recommended general use.
Requires manual activation and deactivation through my.wafe.eu.
For other than default factory setting login to
my.wafe.eu
web application, activate the
Weekly mode
and
set your own time schedule. Remember to confirm the new setting!
HOLIDAY
[OUT]
Unit is in low power mode and ventilates the house once a day.
Suitable when leaving the ventilated areas for extended periods of time.
Requires manual activation and deactivation through
my.wafe.eu
.
SLEEP
[STAND-BY]
The unit is in low power mode, communicates over the internet (if connected) but does not
ventilate.
Turn on before unplugging from the power outlet.
Requires manual activation and deactivation through
my.wafe.eu
or via unit’s control panel.
Part of the transition to
Sleep mode
is a drying process: the unit closes its exterior flaps and the heat
exchanger and dries for 10 minutes.
Unplugging the unit from the power outlet during this step might
result in residual moisture staying inside the unit.
OFF
The unit is unplugged from the power outlet: it does not ventilate and does not communicate
over the internet even if connected.
Not recommended: consider using the Sleep mode instead.
Switch the unit into
Sleep mode
(wait for the whole drying process to finish!) and unplug the cable.
ERROR
The unit does not ventilate and is awaiting the error resolution.
Automatically activated mode after encountering any errors.
After switching to
Error mode
, please, follow the steps in section
WAFE 350 Maintenance / Problem solving
.
Table 04:
Operation modes of WAFE 350.
Содержание 350
Страница 1: ...v 1 0 USER MANUAL WAFE 350 Energy Recovery Ventilation Unit...
Страница 2: ......
Страница 11: ...WAFE 350 Energy recovery ventilation 11 Unit technical drawing Figure 04 Technical drawing of the unit...
Страница 12: ...12 WAFE 350 Energy recovery ventilation Unit exploded view drawing Figure 05 Exploded view drawing of the unit...
Страница 26: ...26 Notes NOTES...
Страница 27: ...Notes 27...
Страница 28: ...28 Notes...
Страница 29: ...Notes 29...
Страница 30: ...Exploded view drawing of WAFE 350 For more information and full components list go to p 12 13...
Страница 31: ......