10 | WAFE 350 Energy recovery ventilation
Unit parameters
BASIC
PARAMETERS
Airflow
m³ / h
80
–
350
Temperature limits
°C
-30 to +40
Heat recovery efficiency
%
86
–
97
Humidity recovery efficiency
%
up to 95
External static pressure (ESP)
Pa
150
–
250
OPERATIONAL
PARAMETERS
Airflow reference
m³ / h
120
180
270
External static pressure (ESP) reference
Pa
100
100
100
Heat recovery efficiency
%
96,70
92,80
91,20
Acoustic pressure level
1 m distance
dB
35,4
38
41,5
Acoustic pressure level
2 m distance
dB
30,9
33,5
37
Power input
W
59,1
79,4
137,9
DESIGN
Weight
kg
35
Dimensions (w x h x d)
mm
1075 x 776 x 539
INSTALLATION
Installation room temperature
°C
5
–
40
Installation room relative humidity
% at °C
<70 at 22
Installation position
Vertical installation
COMPONENTS
Body
Expanded polypropylene (EPP)
Heat exchanger
Plastic duct counterflow
Fans
EC CF radial with forward curved blades
Flap system
Enthalpic Flap System (
EFS™
)
Filters
F7 fineness for fresh incoming outdoor air
M5 fineness for stale exhaust air from the building
Control panel
Analog buttons and 4-line display
Sensors
Pressure, temperature and humidity, CO
₂
Sheathing
Aluminium plates with powder coating
Accessories
(upcoming
—
sold separately)
INELS wall remote control
Aromatizer
SIGFOX Internet of Things network connectivity
CONSTRUCTION
READINESS
Ventilation
mm
DN 160/200 mm (inner/outer diameter)
High voltage
230 V AC, 50 Hz
+ 2 m cable with a standard euro connector
Low voltage
(optional)
Ethernet / RJ45 + CAT5e cable
Potential free (dry) one-way button for Intense
ventilation [Boost]
24 V DC servo drive for façade flaps
Sanitary infrastructure
(optional)
Condensate outlet with 5/4" external thread
OPERATIONAL
LOGIC
Modes
Intelligent mode
Weekly mode
Sleep mode [Stand-by]
Holiday [Out]
Summer [By-pass]
Night mode
Functions
Intense ventilation [Boost]
Fireplace ventilation
Circulation
Table 01:
Parameters of the unit.
Содержание 350
Страница 1: ...v 1 0 USER MANUAL WAFE 350 Energy Recovery Ventilation Unit...
Страница 2: ......
Страница 11: ...WAFE 350 Energy recovery ventilation 11 Unit technical drawing Figure 04 Technical drawing of the unit...
Страница 12: ...12 WAFE 350 Energy recovery ventilation Unit exploded view drawing Figure 05 Exploded view drawing of the unit...
Страница 26: ...26 Notes NOTES...
Страница 27: ...Notes 27...
Страница 28: ...28 Notes...
Страница 29: ...Notes 29...
Страница 30: ...Exploded view drawing of WAFE 350 For more information and full components list go to p 12 13...
Страница 31: ......