WAFE 350 Скачать руководство пользователя страница 15

 

WAFE 350 Energy recovery ventilation |  15 

 

Fan 

09

 

The  unit  is  equipped  with  two  electrically 
powered  radial  fans  with  forward  curved 
blades  and  an  integrated constant  airflow 
function.  Even  at  high  speeds  or  sudden 
starts they remain quiet and reliable. 

Filters 

10

 

11

 

The  production  process  of  genuine 

WAFE

 

filters  is  fully  automated:  their  cardboard 
construction is cut by a German laser, syn-
thetic filtration material is sliced at perfect 
right angles by Swiss blades and each piece 
is  air-tightly  isolated  in  the  chamber  vac-
uum sealer machine made in Italy. 

End result is a precise product for the best 
price on the market. 

WAFE 350

 filter portfolio currently contains 

four models with different fineness of filtra-

tion: 

F7

 and 

M5

 (included) provide a high standard of air hygiene; 

F9

 is suited for areas with 

excessive levels of air pollution; and 

F7/AC

 composite filter with added active carbon particles 

filters out various odours and volatile organic compounds (VOC) produced by plants and ani-
mals as well as from cleaners, wall paints, new furniture and some building materials. 

In contrast with other ventilation units that ask for filter replacement in pre-set time 
intervals (often too early or too late) 

WAFE 350

 

thanks to its just-in-time technol-

ogy

 monitors the 

real

 state of filter clogging. We do so by examining the growing 

pressure drop as detected by our pressure sensors and smart internal logic. 

Earning money by selling you filters you don’t 

really need is not what we do. 

The need for filter replacement is indicated by yellow glowing diode on the control panel of the 
unit, digitally via e-mail or via personal notification on 

my.wafe.eu

 (if the unit is connected). For 

more information, see 

WAFE 350 Maintenance / User maintenance / Replacing the filters

Control panel 12 

Pulling down the black decorative plate reveals a simple four-line, two colour LCD 

WAFE 350

 

control panel with two confirmation and two selection buttons and an information LED diode. 

Nothing else is needed to control the basic functions of your unit - properly installed device 

 

Figure 07: 

Powerful radial fan with 
forward  curved  blades 
propels  the  air  inside 
and  outside  of  your 
unit. 

Содержание 350

Страница 1: ...v 1 0 USER MANUAL WAFE 350 Energy Recovery Ventilation Unit...

Страница 2: ......

Страница 3: ...ery ventilation unit hereinafter manual are to provide safe and economically efficient operation of WAFE 350 energy recovery ventilation unit hereinafter unit Read carefully please Manual and its cont...

Страница 4: ...n box 123 refer to the Figure 05 Exploded view drawing of the unit and Table 02 List of components Intended use WAFE 350 energy recovery ventilation unit is an air ventilation device with an active he...

Страница 5: ...with the use of the space in which the unit is installed In case of damaged power supply it must be replaced by manufacturer his service tech nician or equally qualified person To prevent damage and...

Страница 6: ...so they would not interfere with your daily routine you do not need to fiddle with numerous settings only to remem ber to unset them later WAFE units oper ate in Intelligent mode and are equipped with...

Страница 7: ...mes Ventilation with heat recovery became the only suitable alternative Heat recovery basics Heat Recovery Ventilation HRV efficiently uses energy of waste stale air ejected out of the building with h...

Страница 8: ...ir when temperatures are low hence saving even more on electricity costs keeps a natural and healthy levels of humidity in your home even without using expensive membrane heat ex changers asks for a f...

Страница 9: ...Holiday mode Out Unit is in low power mode and ventilates the house once a day Suitable when leaving the ven tilated areas for extended periods of time Re quires manual activation and deactivation thr...

Страница 10: ...CF radial with forward curved blades Flap system Enthalpic Flap System EFS Filters F7 fineness for fresh incoming outdoor air M5 fineness for stale exhaust air from the building Control panel Analog b...

Страница 11: ...WAFE 350 Energy recovery ventilation 11 Unit technical drawing Figure 04 Technical drawing of the unit...

Страница 12: ...12 WAFE 350 Energy recovery ventilation Unit exploded view drawing Figure 05 Exploded view drawing of the unit...

Страница 13: ...r air pipes and a space for mounting unit s electronic sys tems Bottom body 02 In addition to firmly anchoring unit s mechanical parts the bot tom EPP includes a condensate outlet in case you plan to...

Страница 14: ...lthy humidity back into your home This advantage is offset however by their low efficiency high freezing temperature and the fact they need to be replaced every 5 to 6 years thus increasing the costs...

Страница 15: ...ants and ani mals as well as from cleaners wall paints new furniture and some building materials In contrast with other ventilation units that ask for filter replacement in pre set time intervals ofte...

Страница 16: ...WAFE 350 Op eration Operation modes respond flexibly to any changes increase ventilation intensity on the fly or prevent potential damages Sheathing 16 17 18 19 20 21 22 23 Unit s cover plates are ma...

Страница 17: ...me of installation the place of installation is pre pared in accordance to the document Construction readiness WAFE 350 En ergy recovery ventilation unit For the latest version of the document ask you...

Страница 18: ...to the project and building readiness None SETTING UP THE UNIT Turning the unit on connecting it to PC and setting it according to project pa rameters via WAFE Setup app None USER REGISTRATION Creatin...

Страница 19: ...ting HOLIDAY OUT Unit is in low power mode and ventilates the house once a day Suitable when leaving the ventilated areas for extended periods of time Requires manual activation and deactivation throu...

Страница 20: ...re 08 are used to choose between Option 1 Left 2 Right see Figure 09 Pressing the Confirmation button always activates the option on the topmost line of unit display To select a different option scrol...

Страница 21: ...othing Do not unplug the unit from the power grid Table 05 LED light modes and related unit states Remote control via my wafe eu web application Remote control of the unit is possible only if The unit...

Страница 22: ...o avoid the formation of negative pressure inside your home when operating the unit along with the fireplace the Fireplace ventilation function must be activated during the whole time the fireplace is...

Страница 23: ...the end of a lifetime on the unit display or on my wafe eu signals that fresh F7 ex haust M5 filter has exceeded a recommended degree of clogging The unit remains functional until the filter clogging...

Страница 24: ...r will au tomatically move into its up per end position Cleaning the air diffusers Air diffusers optimise the direction and flow of intake and exhaust air For better air permea bility it is required t...

Страница 25: ...effects of electromagnetic interference etc The warranty also does not cover normal wear and tear Responsibility WAFE 350 energy recovery ventilation unit has been developed and manufactured for use i...

Страница 26: ...26 Notes NOTES...

Страница 27: ...Notes 27...

Страница 28: ...28 Notes...

Страница 29: ...Notes 29...

Страница 30: ...Exploded view drawing of WAFE 350 For more information and full components list go to p 12 13...

Страница 31: ......

Страница 32: ...USER MANUAL WAFE 350 ENERGY RECOVERY VENTILATION UNIT v1 0 WAFE s r o Kolbenova 931 40b 19000 Prague 9 Vyso any e mail info wafe eu phone 420 273 139 700 web www wafe eu...

Отзывы: