Troubleshooting
CoolMatic
56
Compressor is not running (connected to AC supply)
Poor cooling, increase in interior temperature
Unusual noises
Problem
Possible cause
Remedy
No voltage
Connection supply line interrupted
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is present but
the compressor doesn't
run
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
Problem
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor does not
run often
Battery capacity exhausted
Charge the battery
Problem
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (touching the wall)
Bend the component
carefully away from the
obstruction
There is a foreign object stuck
between the cooling unit and the wall
Remove the foreign object
Fan noise
–
Содержание CoolMatic CRX50
Страница 2: ...CoolMatic 3 CRX 50 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 65 2...
Страница 3: ...CoolMatic 4 1 2 3 5 4 6 7 CRX 80 3 4 1 2 3 5 4 6 7 CRX 110...
Страница 4: ...CoolMatic 5 5 5 1 2 3 5 4 6 7 CRX 140 1 2 3 4 6 5 7 8 6 CRX50 CRX65 CRX80...
Страница 5: ...CoolMatic 6 7 CRX110 CRX140 1 2 3 4 6 5 8 7 1 4 3 2 ca 50 mm 8...
Страница 6: ...CoolMatic 7 2 1 9 1 2 0...
Страница 7: ...CoolMatic 8 a b c...
Страница 8: ...CoolMatic 9 mm l m 12 V 24 V 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 6 10 14 d 1 rt sw e 1 2 f...
Страница 9: ...CoolMatic 10 1 Vent Lock g 380 534 500 CRX 50 h CRX 65 448 525 545 i...
Страница 10: ...CoolMatic 11 CRX 80 475 640 528 j CRX 110 520 745 558 k...
Страница 11: ...CoolMatic 12 CRX 140 525 812 620 l...