EN
CoolMatic
Troubleshooting
55
Compressor does not run (battery connection)
Problem
Possible cause
Remedy
U
Term
= 0 V
There is an interruption in the bat-
tery–electronics connection
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
U
Term
≤
U
ON
Battery voltage is too low
Charge the battery
Start attempt with
U
Term
≤
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low
Replacing the battery
Cable cross section too small
Replace the cable
(fig.
d
, page 9)
Start attempt with
U
Term
≥
U
ON
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
U
Term
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
Содержание CoolMatic CRX50
Страница 2: ...CoolMatic 3 CRX 50 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 65 2...
Страница 3: ...CoolMatic 4 1 2 3 5 4 6 7 CRX 80 3 4 1 2 3 5 4 6 7 CRX 110...
Страница 4: ...CoolMatic 5 5 5 1 2 3 5 4 6 7 CRX 140 1 2 3 4 6 5 7 8 6 CRX50 CRX65 CRX80...
Страница 5: ...CoolMatic 6 7 CRX110 CRX140 1 2 3 4 6 5 8 7 1 4 3 2 ca 50 mm 8...
Страница 6: ...CoolMatic 7 2 1 9 1 2 0...
Страница 7: ...CoolMatic 8 a b c...
Страница 8: ...CoolMatic 9 mm l m 12 V 24 V 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 6 10 14 d 1 rt sw e 1 2 f...
Страница 9: ...CoolMatic 10 1 Vent Lock g 380 534 500 CRX 50 h CRX 65 448 525 545 i...
Страница 10: ...CoolMatic 11 CRX 80 475 640 528 j CRX 110 520 745 558 k...
Страница 11: ...CoolMatic 12 CRX 140 525 812 620 l...