CB-36, CB-40, CB-110, RHD-50
Troubleshooting
33
Cooling capacity drops, interior temperature rises
Unusual noises
Fault
Possible cause
Remedy
Compressor runs for a
long time/continuously
Vaporiser iced over
Defrost the vaporiser
Ambient temperature too high
–
Insufficient ventilation
Move the cooling device
Condenser is dirty
Clean the condenser
Fan defective (if installed)
Replace the fan
Compressor runs
infrequently
Battery capacity exhausted
Charge the battery
Fault
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (lies against the
wall)
Bend the component
carefully
Foreign body jammed between the
cooling device and the wall
Remove the foreign body
Fan noise (if installed)
–