Installing and connecting the cooling device
CB-36, CB-40, CB-110, RHD-50
26
➤
Determine the required cross section of the cable in relation to the cable
length according to fig.
5
, page 4.
Key for fig.
5
, page 4
e
Caution!
Make sure that the polarity is correct.
➤
Connect the red lead to the positive terminal.
➤
Connect the black lead to earth.
➤
Before starting up the device for the first time, check whether the operat-
ing voltage and the battery voltage correspond (see type plate).
➤
Connect the cooling device
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at
24 V).
e
Caution!
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
The cooling device is equipped with an electronic device to protect against
reversing the polarity and short circuits when connecting to a battery.
To protect the battery, the cooling device switches off automatically if the volt-
age is insufficient (see table below).
Co-ordinate axis
Meaning
Unit
l
Cable length
m
∅
Cable cross section
mm²
12 V
24 V
Switch-off voltage
10.4 V
22.8 V
Switch-on voltage
11.7 V
24.2 V
_CB_RHD_Kühlboxen.book Seite 26 Montag, 27. September 2010 5:23 17
Содержание CoolMatic CB-36