Initial start-up
ASC 5300 G
84
7.7
Editing default values
The AirConServiceCenter has preset values for the most important ser-
vice tasks. The default values appear automatically when you select the
respective menu.
You can alter the following default values if necessary:
1. In the basic menu, use the cursor keys
or
to select
“Other
selections”
:
2. Press
ENTER
to confirm.
3. Use the cursor key
to select
“Service”
.
4. Press
ENTER
to confirm.
5. Enter the password
“7388”
.
6. Use the keypad and the cursor keys to enter the information.
7. Press
ENTER
to confirm.
8. Press
STOP
to access the standby menu.
Parameter
Default value
Pressure increase test time min.
5
Vacuum time min.
20
Leak test min.
4
PAG oil ml. (additional quantity)
0
UV tracer ml.
0
Filling Qt. g.
500
Print recovery value?
Yes
Short selection
Free selection
Other selections
ENTER-OK
ASC5300G_OPM_DE-EN-ES-FR-RU.book Seite 84 Freitag, 26. Juni 2020 5:42 17
Содержание AirCon Service Center ASC 5300 G
Страница 66: ...DE Technische Daten ASC 5300 G 66 ASC5300G_OPM_DE EN ES FR RU book Seite 66 Freitag 26 Juni 2020 5 42 17...
Страница 132: ...EN Technical data ASC 5300 G 132 ASC5300G_OPM_DE EN ES FR RU book Seite 132 Freitag 26 Juni 2020 5 42 17...
Страница 198: ...ES Datos t cnicos ASC 5300 G 198 ASC5300G_OPM_DE EN ES FR RU book Seite 198 Freitag 26 Juni 2020 5 42 17...
Страница 267: ...FR 267 ASC 5300 G Caract ristiques techniques ASC5300G_OPM_DE EN ES FR RU book Seite 267 Freitag 26 Juni 2020 5 42 17...
Страница 321: ...RU 321 ASC 5300 G 9 9 1 14 K 2 K K ASC5300G_OPM_DE EN ES FR RU book Seite 321 Freitag 26 Juni 2020 5 42 17...
Страница 334: ...RU ASC 5300 G 334 13 2 ASC5300G_OPM_DE EN ES FR RU book Seite 334 Freitag 26 Juni 2020 5 42 17...
Страница 335: ...RU 335 ASC 5300 G ASC5300G_OPM_DE EN ES FR RU book Seite 335 Freitag 26 Juni 2020 5 42 17...