Installation
PS2 500 / PSA2 500
16
wc_tx001592gb.fm
DO NOT measure the insulation resistance with insulation resistance
tester for the following parts. It will cause damage (Model PSA 2 500).
Improper ways to measure insulation resistance
3.6
Discharge Fittings
This pump series is offered with a variety of discharge fittings. Follow
procedures noted below to assure a proper discharge connection.
Threaded Discharge Fitting (BSP)
Tighten hose coupling or discharge pipe securely and with proper
gaskets.
Quick Disconnect Coupling (QD)
Assure coupling is tightened securely to pump discharge fitting and
companion coupling is securely fastened with proper gaskets.
Barbed Discharge Fitting (Barb)
Place hose clamp over hose and push hose to the base of the
discharge fitting. Tighten the hose clamp to secure the hose in place.
1
Between the plug prongs.
2
Between the electrodes on the level relay unit.
3
Between the electrodes on the level relay unit and the plug prongs.
CAUTION
1
2
wc_gr000258
3