PS2 500 / PSA2 500
Installation
wc_tx001592gb.fm
15
may flow back to the pump when the pump is stopped; and if the hose
end is lower than the water surface, water may overflow when the
pump is turned off.
3.3.2
The hose should be run as straight as possible, since excessive
bending will hinder the water flow, preventing sufficient lift, and can
even cause the hose to become clogged with earth. If the hose is
crimped near the pump, air can become trapped in the pump and
cause idle running.
3.3.3
If used in a permanent installation, where the pump is not readily
accessible after installation, please contact Wacker Neuson for a
duplicate nameplate to be installed at the wellhead or on the control
box so that it will be readily visible.
3.4
Preparing for Installation
Before installing the pump at a work site, you will need to have the
following tools and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note:
Please also read the instructions that come with each of the
test instruments.
3.5
Checks to Make Before Installation
When a grounded plug is used:
Use the megohmmeter to measure the insulation resistance between
the cable assembly prongs and ground.
When connection leads are used:
With the megohmmeter, measure the insulation resistance between
each core lead and the ground lead.
Reference insulation resistance: 20M
Ω
or greater
Note:
The reference insulation resistance (20M
Ω
or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation, see “Periodic Maintenance Table.”
CAUTION!
Personal injury hazard. If large quantities of earth are sucked up, damage resulting
from friction in the pump can lead to electrical leakage and shock.
Use the pump in the upright position. To prevent the pump from becoming sub-
merged in mud, mount it on a block or other firm base if necessary.