2.2
Prior to Operation
When the pump is delivered, first perform the following inspection checks:
While unpacking, inspect the product for damage during shipment, and make
sure all bolts and nuts are tightened properly.
Check the model number to make sure it is the product that was ordered. Be
certain it is the correct voltage and frequency.
Note:
If there is any problem with the product as shipped, contact your nearest
dealer or Wacker Neuson representative at once.
2.3
Preparing for Installation
Preparing for
setup
Observe the following points when preparing to install the pump.
Be aware that leakage of pump lubricants may cause pollution of water.
An appropriate plug or electrical connection must be provided according to local
codes and standards. Refer to the wiring diagram.
Use with a power supply voltage within ±5% of the rated voltage.
Operating
Safety
Do not operate the pump if the maximum water pressure in the area exceeds
0.3 MPa–discharge pressure.
Do not use this pump in liquids other than water, such as oil, salt water, or
organic solvents. Contact your Wacker Neuson dealer with questions about
specific fluids.
Do not use in water temperatures outside the range of 0–40°C (32–104°F)
which can lead to failure, electrical leakage, or shock.
Do not use in the vicinity of explosive or flammable materials.
Do not operate the pump if any parts are loose or missing.
2.4
Preparing for installation
Before installing the pump at a work site, you will need to have the following tools
and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note:
Please also read the instructions that come with each of the test instruments.
CAUTION
Personal injury hazard. Failure to observe this caution can lead to electrical shock,
current leakage, fire, water leakage, or other problems.
Do not operate this product under any conditions other than those for which it is
specified.