wc_tx001296gb.fm
19
PS2/PSA2 1503L/2203L
Operation
2.11
Operation
Before
starting
1. Make sure once again that the product is of the correct voltage and frequency
rating.
NOTICE
:
Using the product at other than rated voltage and frequency will not only
lower its performance but may damage the product.
Note:
Confirm the rated voltage and frequency on the model nameplate.
2. Confirm the wiring, supply voltage, circuit breaker capacity, and motor insulation
resistance.
Reference insulation resistance = 20 M
Ω
or greater.
Note:
The reference insulation resistance (20 M
Ω
or greater) is the value when the
pump is new or has been repaired. For the reference value after installation see
“Periodic Maintenance Table.”
3. The setting on the circuit breaker or other overload protector should be made in
accord with the rated current of the pump.
Note:
See “Operating Specifications” for the rated current of the pump.
4. When powering the pump with a generator, be certain the generator is sized to
supply the required power for the pump and any other equipment powered by
the generator.
Safety
considerations
Make sure no extraneous objects such as pins, nails or other metal objects are
sucked into the pump.
Never start the pump while it is suspended. The pump may jerk and crush
extremities.
Never start the pump when people are standing next to it. A current leak can
result in electrical shock.
Never insert your hand or any other object into the inlet opening on the
underside of the pump casing while the pump is connected to the power supply.
The pump may become hot during operation. Do not touch an operating pump.
Allow the pump to cool before handling.
Pay careful attention to the water level while the pump is operating. Dry
operation may cause the pump to malfunction.
Note:
See “Operating Water Level” for the water level necessary for operation.
In case of a power outage, turn off the power to the pump to avoid having it start
unexpectedly when the power is restored.
If the protection system operates due to an overload or malfunction, causing the
pump to stop, first investigate and remove the cause before restarting.
When the pump is not used for an extended period, be sure to turn off the power
(circuit breaker, etc.). Deterioration of the insulation may lead to electrical
leakage, electrical shock, or fire.
WARNING
Personal injury and machine damage hazards.
To avoid personal injury or machine damage, observe the safety considerations
listed below while operating this pump.