11 Maintenance
100_0101_mt_0007.fm
53
Assembling the vibrator head
1. Place pipe thread seal on the thread of the housing.
2. Screw the housing on the connecting piece and tighten with a large pipe
wrench.
3. Place pipe thread seal on the thread of the flexible shaft.
4. Place the vibrator head with the thread on the flexible shaft, while guiding the
shaft core into the shaft core adapter of the vibrator head.
5. Screw the vibrator head on the flexible shaft (Caution! Left-hand thread) and
tighten with large pipe wrench.
6. Let pipe thread seal cure for 24hours.