wc_tx004154gb_FM10.fm
43
HDR 115
Burner Setup
6.5
Adjusting the Air Damper
When
Adjust the air damper when burner performance is in question.
Factory
settings
Air damper: 0.126 in (3.2 mm)
Note: This parameter is factory-set.
Effects
The air setting has the following effects on combustion.
■
Higher O
2
percentage (excess air settings) lowers soot production but raises
stack temperature and reduces efficiency: lean mixture.
■
Lower O
2
percentage (inadequate air settings) increases efficiency and lowers
stack temperature but may cause soot build-up: rich mixture.
Procedure
Perform the procedure below to adjust the air damper.
1. Perform the initial setting of the air damper with the machine shut down.
2. Remove the burner. See topic
Removing and Installing the Burner
Assembly.
3. Loosen the screws
(a)
.
4. Rotate the air damper as necessary.
■
A smaller gap decreases air volume.
■
A wider gap increases air volume.
5. Tighten the screws
(a)
.
6. Re-install the burner. See topic
Removing and Installing the Burner Assembly
.
Result
The air damper has now been adjusted.
wc_gr013179
a
3.2 mm
(0.126 in)