background image

2008-Value_Gen_GV2500A_Q.fm

William Lahner                                                                     Dan Domanski

Vice President of Engineering              Manager, Product Engineering

WACKER NEUSON CORPORATION

Date / Datum / Fecha / Date

EC DECLARATION OF CONFORMITY

CE-KONFORMITÄTSERKLÄRUNG

DECLARACIÓN DE CONFORMIDAD DE LA CE 

DÉCLARATION DE CONFORMITÉ C.E.

WACKER NEUSON CORPORATION, N92 W15000 ANTHONY AVENUE, MENOMONEE FALLS, WISCONSIN USA

 

hereby certifies that the construction equipment specified hereunder / bescheinigt, daß das Baugerät / certifica que la máquina de 
construcción / atteste que le matériel :

1. Category / Art / Categoría / Catégorie

 

Power Generators

Kraftstromerzeuger

Grupos Electrógenos

Groupe Électrogènes de Puissance

2.

Type - Typ - Tipo - Type 

GV 2500A

3.

Item number of equipment / Artikelnummer / Número de referencia de la máquina / Numéro de référence du matériel :

0009345, 0009350, 0009355, 0009360

  

4.

Electric power / Elektrische Leistung / Potencia eléctrica / Force motrice :

2,07 kW

Has been sound tested per Directive 2000/14/EC / In Übereinstimmung mit Richtlinie 2000/14/EG bewertet worden ist / Ha sido 
ensayado en conformidad con la norma 2000/14/CE / A été mis à l’épreuve conforme aux dispositions de la directive 2000/14/CEE :

and has been produced in accordance with the following standards:
und in Übereinstimmung mit folgenden Richtlinien hergestellt worden ist:
y ha sido fabricado en conformidad con las siguientes normas:
et a été produit conforme aux dispositions des directives européennes ci-après :

2000/14/EC
2002/88/EC
89/336/EEC
98/37/EEC

AUTHORIZED REPRESENTATIVE IN THE EUROPEAN UNION
BEVOLLMÄCHTIGTER VERTRETER FÜR DIE EUROPÄISCHE GEMEINSCHAFT
REPRESENTANTE AUTORIZADO EN LA UNIÓN EUROPEA
REPRÉSENTANT AGRÉÉ AUPRÈS DE L’UNION EUROPÉENNE

WACKER CONSTRUCTION EQUIPMENT AG
Preußenstraße 41
80809 München

Conformity Assessment Procedure / 
Konformitätsbewertungsverfahren / 
Procedimiento para ensayar 
conformidad / Procédé pour l’épreuve 
de conformité

Name and address of notified 
body / Bei folgender 
einbezogener Prüfstelle / 
Oficina matriculadora / 
Organisme agrée

Measured sound power level / 
Gemessener Schallleistungspegel / 
Nivel de potencia acústica 
determinado / Niveau de puissance 
acoustique fixé 

Guaranteed sound power level / 
Garantierter Schallleistungspegel / 
Nivel de potencia acústica 
garantizado / Niveau de puissance 
acoustique garanti

Annex VIII / Anhang VIII 

Anexo VIII / Annexe VIII

Société Nationale de 

Certification et 

Homologation L-5201 

Sandweiler# 0499

95 dB(A)

 96 dB(A)

 28.07.08

Содержание GV 2500A

Страница 1: ...Generator GV 2500A OPERATOR S MANUAL 0157385en 004 0908 0 1 5 7 3 8 5 E N...

Страница 2: ...enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outside and far away from wi...

Страница 3: ...Requirements 13 3 2 Installation 15 3 3 Generator Derating 16 3 4 Grounding the Generator 17 3 5 Operating Heavy Loads 17 3 6 Use of Extension Cords 18 3 7 Control Panel 20 3 8 Before Starting 21 3 9...

Страница 4: ...Table of Contents GV 2500A wc_bo0157385en_004TOC fm 4 5 Technical Data 32 5 1 Generator 32 5 2 Engine 33 5 3 Sound Specifications 33...

Страница 5: ...e contact Wacker Neuson Corporation The information contained in this manual was based on machines in production at the time of publication Wacker Neuson Corporation reserves the right to change any p...

Страница 6: ...at follow this symbol to avoid possible injury or death DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which...

Страница 7: ...tructions contained in both this manual and the engine manual and familiarize yourself with the location and proper use of all controls Inexperienced operators should receive instruction from someone...

Страница 8: ...safety guidelines below Failure to follow the warnings and safety standards could result in severe injury or death NEVER install a generator in an enclosed area such as a tunnel or a trench Using a g...

Страница 9: ...ve the machine and allow the machine to dry before servicing 2 3 5 DO NOT service the machine if your clothing or skin is wet 2 3 6 DO NOT allow untrained personnel to service this equipment Only trai...

Страница 10: ...fety Information GV 2500A wc_si000106gb fm 10 2 4 Label Locations wc_gr001289 PETROL G A S O L I N A I S S I N C I BENZIN CALDO H E I S S HOT C H A U D D A N G E R G E F A H R P E L I G R O D A N G E...

Страница 11: ...labels where needed These labels are described below Label Meaning WARNING Hot surface Close the choke Gasoline Potential Earth WARNING Electric shock will cause serious injury or death WARNING Electr...

Страница 12: ...g the model number item number revision number and serial number is attached to each unit Please record the infor mation found on this plate so it will be available should the nameplate become lost or...

Страница 13: ...g This means that the amount of power needed to initially start the equipment is larger than the power required to keep it running The generator must be capable of supplying this surge current Other t...

Страница 14: ...cal tools often require a large starting current The amount of starting current depends on the type of motor and its use Most electrical tools require 1 2 3 times their stated wattage for start ing Lo...

Страница 15: ...e moisture Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use this generator inside a home or garage EVEN I...

Страница 16: ...e also affects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000...

Страница 17: ...stud to earth ground Refer to local codes if machine is used to power a building or similar distribution system 3 5 Operating Heavy Loads Limit operations requiring the maximum rated output of the gen...

Страница 18: ...are or frayed cords Replace damaged cords immediately Do not exceed the rating of the cord Contact the cord manufacturer if in doubt about cord use Choose the cord size from the Minimum Extension Cord...

Страница 19: ...25 50 100 200 Cross sectional area of wire in mm2 2 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 4 1 5 1 5 1 5 2 5 1 5 1 5 1 5 1 5 6 1 5 1 5 1 5 4 1 5 1 5 1 5 2 5 8 1 5 1 5 2 5 6 1 5 1 5 1 5 2 5 10 1 5 1 5 4 6 1 5...

Страница 20: ...rements do not exceed the power rating of the generator or the current limit of the receptacles When the circuit breaker opens the button will pop out To reset circuit breaker push button in Note Enla...

Страница 21: ...understand safety and operating instructions at beginning of this manual 3 8 2 Read and understand the meanings of all warning and operating labels 3 8 3 Check oil level in engine fuel level conditio...

Страница 22: ...pe d Note If the oil level in the engine is low the engine will not start If this happens check oil level and add oil as needed 3 9 5 Open choke as engine warms 3 9 6 Allow engine to warm up a few min...

Страница 23: ...nance Schedule Daily before starting After first 20 hrs Every 50 hrs Every 100 hrs Every 300 hrs Check fuel level Check engine oil level Inspect air filter Replace as needed Check external hardware Cl...

Страница 24: ...of environmental protection place a plastic sheet and a container under the machine to collect any liquid that drains off Dispose of this liquid in accordance with environmental protection legislatio...

Страница 25: ...solvents for cleaning the air cleaner A fire or explosion could result To service 4 4 1 Release latches a on the top and bottom of the air cleaner cover b and remove the cover 4 4 2 Check the filter...

Страница 26: ...ng the engine Do not touch the muffler while it is hot Note Refer to section Technical Data for the recommended spark plug type and the electrode gap setting 4 5 1 Remove the spark plug and inspect it...

Страница 27: ...gine to the proper speed Turn the speed adjusting screw a in or out to obtain a no load speed of 3100 rpm NOTICE Setting the engine speed too high or too low may damage tools and other appliances atta...

Страница 28: ...ed with a limiter cap to prevent excessive enrichment of the air fuel mixture in order to comply with emission regulations The mixture is set at the factory and no adjustment should be necessary Do no...

Страница 29: ...ngine oil into the cylinder Crank the engine a few turns to distribute the oil to the inside of the cylinder walls 4 8 6 Pull the starter rope slowly until resistance is felt and leave the handle in t...

Страница 30: ...should be closed when starting a cold engine All loads are disconnected from generator Spark plug is in good condition Spark plug cap is tight Engine oil level is adequate If engine starts but there i...

Страница 31: ...Diode 2 Auxiliary Winding 6 Surge Absorber 3 Capacitor 7 Circuit Breaker 4 Rotor Windings 8 Receptacle 230V 16 Amp Wire Colors B Black V Violet Or Orange G Green W White Pr Purple L Blue Y Yellow Sh S...

Страница 32: ...utput W 2070 Type Single voltage single phase Brushless capacitor regulator system AC Voltages Available Volts phase 230 1 Frequency Hz 50 Power Factor 0 9 AC receptacles 230V 16Amp Schuko 230V 16Amp...

Страница 33: ...d according to ISO 3744 for the sound power level LWA Model GV 2500A Engine Engine Make Honda Engine Model GX160K1 VPM4 Max rated power rated speed kW Hp 3 6 4 8 3600 rpm Spark Plug NGK ND BPR6ES W20E...

Страница 34: ......

Страница 35: ...aux dispositions de la directive 2000 14 CEE and has been produced in accordance with the following standards und in bereinstimmung mit folgenden Richtlinien hergestellt worden ist y ha sido fabricado...

Страница 36: ...0 Fax 49 0 89 3 54 02 3 90 Wacker Neuson Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Asia Pacific Operations Skyline Tower Suite 23...

Отзывы: