![Wacker Neuson GV 2500A Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/wacker-neuson/gv-2500a/gv-2500a_operators-manual_3162308030.webp)
Maintenance
GV 2500A
wc_tx000270gb.fm
30
4.10 Troubleshooting
Problem / Symptom
Reason / Remedy
If engine doesn't start, check
that:
•
Engine switch is on "Start".
•
Fuel valve is open.
•
Fuel tank has fuel.
•
Choke lever is in correct position. Choke should be
closed when starting a cold engine.
•
All loads are disconnected from generator.
•
Spark plug is in good condition.
•
Spark plug cap is tight.
•
Engine oil level is adequate.
If engine starts but there is no
power at receptacles, check
that:
•
Circuit breaker is closed.
•
Wiring from generator to receptacles is tight.
If engine starts but runs errati-
cally, check:
•
Condition of air filter.
•
Condition of spark plug and plug cap.
•
Freshness of fuel.