Troubleshooting Voltage Issues
GPS 8500/GPS 9700
wc_tx000828gb.fm
18
3.2
Flashing the Generator
Prerequisites
12V battery
Multimeter
Procedure
Follow the procedure below to flash the generator.
1. Shut down the generator.
2. Disconnect all loads from the generator.
3. Place the auto idle switch in the OFF position.
4. Remove the rear panel
(a)
from the generator.
5. Disconnect the F1 (+) and F2 (-) wires and the L1 and L2 wires from the
Automatic Voltage Regulator (AVR)
(b)
.
6. Start the engine.
7. Check the engine rpm. It should be approximately 3750 rpm.
8. Connect the 12V battery to the F1 (+) and F2 (-) wires; battery positive to F 1
(+), battery negative to F2 (-).
9. Measure the voltage between the L1 wire and the L2 wire.
Is 120–160 VAC measured?
10.Reassemble the generator.
This procedure continues on the next page.
WARNING
Electric shock hazard. High voltage exists at the L1 and L2 wires. Electric shock
can cause severe injury or death.
f
Never touch the L1 and L2 wires while the engine is running.
WARNING
Explosion hazard. Batteries produce hydrogen gas during normal operation.
f
Keep sparks away from the battery.
Yes ____
No ____
Continue
Check the stator windings.
Содержание GPS 8500
Страница 1: ...Generator GS 8 5V GPS 8500 GS 9 7V GPS 9700 REPAIR MANUAL 0174423en 002 0809 0 1 7 4 4 2 3 E N ...
Страница 2: ......
Страница 11: ...GPS 8500 GPS 9700 Safety Information wc_si000252gb fm 11 Notes ...
Страница 34: ...Disassembly and Assembly GPS 8500 GPS 9700 wc_tx000829gb fm 34 4 5 Generator Exploded View ...
Страница 45: ...GPS 8500 GPS 9700 Disassembly and Assembly wc_tx000829gb fm 45 Notes ...
Страница 55: ......