Note
T00871GB.fm
12
Caution:
Due to the high stray current levels of the interference filter,
make sure that the inverter is only connected to one fault
current protective switch. This will prevent the fault current
protective switch from being triggered inadvertently.
3.3
Class rating III (protective low voltage)
Protective low voltage are rated voltages up to 50 V of AC current. The
protective low voltage prevents the build-up of a dangerous contact
voltage.
Safety transformers are permitted for generating protective low
voltages for which the low-voltage side has no conductive connection
to the power supplying network.
The inverter must be grounded with the grounded conductor
connection!