Operation
CT 36-400E
18
2.4
Installing Plugs and Power Cords
See Graphic: wc_gr0001177
The trowel comes with a 5-prong plug for connecting to 400V, 3Ø
power.
To reduce the risk of electric shock, only a certified electrician should
install or service power plugs, cords, or electrical boxes.
2.5
Connecting to Power Supply
To reduce the risk of electric shock, all equipment must be properly
grounded. Connect this trowel to grounded receptacles and extension
cords only. Make sure power supply has either an Earth Leakage
Circuit Breaker (ELCB) or an isolation monitor in the circuit.
2.5.1
Check that the motor On/Off switch on the trowel is in the “0” (stop)
position before connecting to a power source.
2.5.2
Make sure the power supply matches the voltage requirements listed
on motor label. Running the trowel at a low voltage will cause it to run
slow. This will reduce performance and cause the motor to overheat.
2.5.3
This machine must be grounded while in use to protect the operator
from electric shock.
WARNING
DANGER
Содержание CT 36-400E
Страница 1: ...Trowel CT 36 400E OPERATOR S MANUAL 0159491en 002 1108 0 1 5 9 4 9 1 E N ...
Страница 2: ......
Страница 4: ...Foreword wc_tx000001gb electric fm 4 ...
Страница 11: ...CT 36 400E Safety Information 11 1 4 Label Locations l o 2 l 2 l o o l l 2 l 2 o ...
Страница 25: ...CT 36 400E Operation 25 1 2 wc_gr003239 a b c d ...
Страница 32: ...Maintenance CT 36 400E 32 Notes ...
Страница 36: ......
Страница 37: ......
Страница 50: ...AEM_ConcretePowerTrowel qxd 7 23 03 6 31 AM Page 1 ...