![Wacker Neuson BS Series Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/wacker-neuson/bs-series/bs-series_operators-manual_3179520030.webp)
10 Maintenance
30
100_0201_mt_0004.fm
8. Screw the oil sight glass back on, but do not tighten.
9. Stand the vibratory rammer upright to check the oil level.
10.If necessary, top off the oil until the oil sight glass is 1/2 to 3/4 filled.
11.Then tighten the oil sight glass. The torque setting is 9 Nm.
12.Wipe the area of the oil sight glass with a clean cloth.
10.2.6
Oil change
1. Remove dirt accumulation within the range of the oil sight glass.
2. Screw on the oil sight glass. Clean the thread on the oil sight glass and wrap with Teflon tape.
3. Tilt the vibratory rammer backward until it rests on the control handle and the drain the used oil into
a suitable reservoir.
4. Tilt the vibratory rammer forward and secure in this position.
5. Fill oil through the opening in the oil sight glass in the housing. For the oil specification, see chapter
Technical Data
.
6. Screw the oil sight glass back on, but do not tighten.
7. Stand the vibratory rammer upright to check the oil level.
8. If necessary, top off the oil until the oil sight glass is 1/2 to 3/4 filled.
9. Then tighten the oil sight glass to a torque setting of 9 Nm.
10.Wipe the area of the oil sight glass with a clean cloth.
NOTICE
Used oil must be disposed of according to the applicable local environmental protection
regulations.
NOTICE
This process can take up to 10 minutes.
Содержание BS Series