10 Maintenance
28
100_0201_mt_0004.fm
1. Remove the air cleaner (filter) cover.
2. Remove the main filter element and the prefilter and check for holes or cracks. Replace the filter
elements if necessary.
Main filter element: Replace the filter element if very contaminated.
Prefilter: Only use low-pressure compressed air to clean the prefilter. If highly contaminated, the
filter element must be washed out with a mild cleaning agent and warm water. Rinse with clean
water. Allow to dry completely prior to installation.
3. Wipe out the air cleaner (filter) housing with a clean cloth. Do not use any compressed air!
4. Ensure that the contaminant ejection slot of the prefilter is clean.
5. Insert both filter elements into the air cleaner (filter) housing and screw on the air cleaner (filter) cover.
10.2.5
Check/top off the oil level
1. Remove dirt accumulation within the range of the oil sight glass.
NOTICE
During cleaning, no grime may get into the intake port of the engine. This may cause
engine damage.
Item
Designation
1
Air cleaner (filter) cover/air filter
NOTICE
Do not oil or lubricate the prefilter.
NOTICE
If the vibratory rammer was transported in a horizontal position or was just relocated, it
must be put in a vertical position for 15 minutes before the oil level can be checked.