Commissioning
7.2 Tests before commissioning
Ground conditions
The maximum dumping height depends on several factors of the ground
conditions. An exact specification of this value is not possible.
▪
Determine the maximum fill height by compaction tests or soil
samples.
Shaking in cobblestones
▪
To avoid damage to the machine or compaction material, use a slid-
ing device,
.
Compaction of asphalt
▪
To avoid cracking and sticking to the asphalt, use water tank with
sprinkler system,
see Accessories on page 49
.
7.2
Tests before commissioning
Information
Further information and detailed descriptions,
see Mainten-
ance on page 38
.
Perform the following checks:
• Check machine and components for damage.
–
Do not put the damaged machine into operation. Damages and
defects must be repaired immediately.
• Check the fuel level.
• Check fuel lines for leaks.
• Check air filter.
• Check engine oil fill level.
• Check reversing starter.
• Check to ensure the screw connections are firmly seated.
• Check control elements for functionality.
7.3
Putting into operation with Honda engine
WARNING
Danger of burns due to starting aid sprays!
Starting aid sprays can ignite and cause severe burns.
►
Do not use any starting aid sprays.
34
Operator’s Manual | BPS1030A, BPS1135A, BPS1340A, BPS1550A, BPS2050A | BPS | 5100060577 | 01/2023 |
Version: 5 | [en]
Содержание BPS1030A
Страница 59: ... en Version 5 01 2023 5100060577 BPS1030A BPS1135A BPS1340A BPS1550A BPS2050A BPS Operator s Manual 59 Notes ...