Commissioning
Electrical connection 8.5
25
[en-US] | 02/2022 | 5100063562 | AR54-64 | Operator’s Manual
NOTICE
Note: When mounting on formwork!
►
Comply with all instructions and hazard warnings in this manual.
►
Observe the assembly instructions for the clamping device and com-
ply with the directions and hazard warnings contained therein.
1.
Hole pattern dimensions, see
2.
Remove dirt in the area of the contact surfaces.
3.
Fasten the machine to the formwork with screws, washers and nuts.
4.
Secure screws and nuts with suitable locking agents.
Machine type
Bolt/nut fasteners
Strength class
Standard
Tightening torque
AR54
AR64
M16
8.8/8
Screw:
DIN EN ISO 4014,
DIN EN ISO 4017,
DIN EN ISO 4762
Nut
DIN EN ISO 4032
Washer
DIN 7989, DIN 1543
210 Nm
8.5
Electrical connection
Connect machine to power source
WARNING
Danger from electric current.
Risk of injury from electric current in the event of improper work.
►
Repairs and a subsequent safety check may only be performed by a
qualified electrician according to the applicable guidelines.
CAUTION
Improper handling can cause damage
►
Unplug other electrical equipment from the generator before turning
on the machine.
►
Remaining generator power must not be exceeded for connecting
additional electrical devices.
8