OM 803 us – Edition 3.7 * 803b330.fm
3-15
Operation
Jump-starting the engine (supply battery)
Safety instructions
• Never jump-start the engine if the battery of the machine is frozen – explosion hazard!
☞
Dispose of a frozen battery!
• The excavator must not touch the jump-starting vehicle when connected with jump
leads – sparking hazard!
• The external power source must deliver 12 V; higher supply voltages will damage the
electrical system of the vehicles!
• Use only authorized battery jumper cables which conform to the safety requirements
and which are in perfect condition!
• The jump lead connected to the positive
+
terminal of the starting battery must never be
brought into connection with electrically conductive vehicle parts
– short circuit hazard.
• Route the jump leads so that no one can catch on rotating components in the engine
compartment!
Procedure
☞
Move the jump-starting vehicle close enough to the machine so that the jump leads can
reach to connect the two batteries
☞
Let the engine of the jump-starting vehicle run
☞
First connect one end of the red jump lead (
+
) to the
+
terminal of the empty battery,
then connect the other end to the
+
terminal of the starting battery
☞
Connect one end of the black jump lead (
–
) to the
–
terminal of the starting battery
☞
Connect the other end of the black cable (
–
) to a solid metal component fimly screwed
on the engine block or onto the engine block itself. Do not connect it to the negative ter-
minal of the empty battery, as otherwise explosive gas emerging from the battery can
ignite if sparks are formed!
☞
Start the engine of the machine with the empty battery
Once the engine has started:
☞
With the engine running, disconnect both jump leads in exactly the reverse order (first
remove the
–
terminal, then the
+
terminal) – this prevents sparking in the vicinity of
the battery!
12 V
12 V
34001b710 05 eps
Fig. 54: Starting aid with battery jumper cables
Empty battery
Starting
battery
Содержание 803 dual power
Страница 32: ...1 22 OM 803 us Edition 3 7 803b110 fm Introduction...
Страница 50: ...2 18 OM 803 us Edition 3 7 803b210us fm Safety instructions Check track tension at regular intervals...
Страница 54: ...2 22 OM 803 us Edition 3 7 803b210us fm Safety instructions...
Страница 184: ...5 44 OM 803 us Edition 3 7 803b560 fm Maintenance...
Страница 200: ...6 16 OM 803 us Edition 3 7 803b610 fm Technical data...