Maintenance
Air filter (from serial no. AI00876)
Replacing air filter elements
Replace the air filter elements:
• If the yellow piston
B
in dirt indicator
A
reaches the red service mark
C
.
• Every 1000 operating hours or once a year at the latest.
1
Park the machine, stop the engine, remove the starting key and carry it with you.
2
Open the engine cover.
3
Remove dirt and dust from the air filter housing and the area around it.
4
Fold bow clips
D
on lower housing section
E
to the outside.
5
Remove lower housing section
E
.
M
6
Carefully remove outside filter
G
with slightly turning movements.
7
Ensure that all contamination (dust) inside the upper and lower housing sections
(including the dust valve) has been removed.
8
Clean the parts with a clean lint-free cloth, do not use compressed air.
9
Carefully remove inside filter
H
with slightly turning movements.
10
Check the new inside filter
H
and outside filter
G
for damage and carefully insert
them in the air filter housing.
11
Close bow clips
D
.
12
Ensure that dust valve
F
shows downward once it is installed.
13
After replacing the filters, press button
J
to reset the yellow piston
B
.
Fig. 199: Indicator for air filter contamination
A
C
B
J
F
E
Fig. 200: Lower housing section
D
Fig. 201: Outside filter
G
Fig. 202: Inside filter
H
Содержание 803 dual power
Страница 32: ...1 22 OM 803 us Edition 3 7 803b110 fm Introduction...
Страница 50: ...2 18 OM 803 us Edition 3 7 803b210us fm Safety instructions Check track tension at regular intervals...
Страница 54: ...2 22 OM 803 us Edition 3 7 803b210us fm Safety instructions...
Страница 184: ...5 44 OM 803 us Edition 3 7 803b560 fm Maintenance...
Страница 200: ...6 16 OM 803 us Edition 3 7 803b610 fm Technical data...