wc_tx000177gb.fm
23
PG 2A / 3A
Operation
4.3
Before Starting
1. Read safety instructions at the beginning of this Operator’s Manual.
2. Place pump as near to water as possible, on a firm, flat, level surface.
3. To prime pump, remove prime plug
(a)
and fill pump housing with water. If the
pump housing is not filled with water before starting, it will not begin pumping.
WARNING
Do not open priming plug, discharge plug, or loosen hose fittings if
pump is hot! Water or vapor inside pump may be under pressure.
4. Check for leaks between pump and engine. If water is leaking, the seal inside
pump is worn or damaged. Continued operation may cause water damage to
engine.
5. Check that hoses are securely attached to pump. Suction hose
(b)
must not
have any air leaks. Tighten hose clamps
(c)
and couplings
(d)
. Check that
discharge hose
(e)
is not restricted. Lay hose out as straight as possible.
Remove any twists or sharp bends from hose which may block the flow of water.
6. Make sure suction strainer
(f)
is clean and securely attached to end of hose.
The strainer is designed to protect the pump by preventing large objects from
being pulled into the pump.
NOTICE:
Strainer should be positioned so it will remain completely under water.
Running the pump with the strainer above water for long periods can damage the
pump.
7. Check fuel level, engine oil level, and condition of air cleaner.
WARNING
e
a
d
c
b
c
f
wc_gr000835