5-28
BA 901/1101 en – Edition 2.1 * 91101b530.fm
Maintenance
Servicing and maintenance at regular intervals
Before performing machine travel
☞
Check every time before performing machine travel:
• Is the light system OK?
• Is the signaling and warning system OK?
Every week
☞
Check once a week:
Fuse box behind the seat on the left
• Cable and grounding connections
• Battery charge condition
• Condition of battery terminals
Instructions concerning specific components
Cables, bulbs and fuses
Always observe the following instructions:
• Malfunctioning components of the electrical system must always be replaced by an
authorized technician. Bulbs and fuses may be changed by unqualified persons.
• When performing maintenance on the electrical system, pay particular attention to
ensuring good contact in leads and fuses.
• Blown fuses indicate overloading or short circuits. The electrical system must therefore
be checked before installing the new fuse.
• Only use fuses with the specified load capacity (amperage)
Alternator
Always observe the following instructions:
• Only test run the engine with the battery connected.
• When connecting the battery, ensure that the poles (+/
−
) are not inverted.
• Always disconnect the battery before performing welding work or connecting a quick
battery charger.
• Have malfunctioning charge indicator lights immediately replaced
Содержание 1101C
Страница 10: ...I 8 BA 901 1101 en Edition 2 1 Ba91101en2_1SIX fm Index...
Страница 34: ...1 24 BA 901 1101 en Edition 2 1 91101b110 fm Introduction...
Страница 46: ...2 12 BA 901 1101 en Edition 2 1 91101b210 fm Safety instructions...
Страница 50: ...3 4 BA 901 1101 en Edition 2 1 91101b320 fm Operation 3 3 Instrument panel overview...
Страница 122: ...3 76 BA 901 1101 en Edition 2 1 91101b340 fm Operation...
Страница 166: ...5 42 BA 901 1101 en Edition 2 1 91101b560 fm Maintenance Maintenance plan model 1101...