background image

Copyright 

notice

© Copyright 2019 by Wacker Neuson Production Americas LLC
All rights, including copying and distribution rights, are reserved.
This publication may be photocopied by the original purchaser of the machine. Any 
other type of reproduction is prohibited without express written permission from 
Wacker Neuson Production Americas LLC.
Any type of reproduction or distribution not authorized by Wacker Neuson Production 
Americas LLC represents an infringement of valid copyrights. Violators will be 
prosecuted. 

Trademarks

All trademarks referenced in this manual are the property of their respective owners.

Manufacturer

Wacker Neuson Production Americas LLC
N92W15000 Anthony Avenue
Menomonee Falls, WI 53051 U.S.A.
Tel: (262) 255-0500 · Fax: (262) 255-0550 · Tel: (800) 770-0957
www.wackerneuson.com

Original 

instructions

This Operator’s Manual presents the original instructions. The original language of this 
Operator’s Manual is American English.

Содержание 0009112

Страница 1: ...5000188001 07 0719 5 0 0 0 1 8 8 0 0 1 Operator s Manual Pump PST2 400 PSTF2 400 EN...

Страница 2: ...distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights Violators will be prosecuted Trademarks All trademarks referenced in this manual are...

Страница 3: ...NG Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer birth defects and other reproductive harm WARNING Cancer and Reproductive Harm www P65Warning...

Страница 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm This page is intentionally left blank...

Страница 5: ...modifications even without notice which improve the performance or safety standards of its machines The information contained in this manual is based on machines manufactured up until the time of pub...

Страница 6: ...Foreword PST2 400 6 wc_tx002043gb fm...

Страница 7: ...ng for Installation 18 3 4 Checks to Make Before Installation 18 3 5 IInstalling the Float if equipped 19 3 6 Electrical Wiring 20 3 7 Connecting the Power Supply 21 3 8 Cable Assembly 22 4 Operation...

Страница 8: ...8 wc_bo5000188001_07TOC fm Table of Contents PST2 400 6 Technical Data 36 6 1 Standard Specifications 36 6 2 Operating Specifications 37 6 3 Dimensions 38 7 Schematics 39 8 AEM Safety Manual 41...

Страница 9: ...ial personal hazards Obey all safety messages that follow this symbol DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury To avoid death or seriou...

Страница 10: ...persons in the area Machine damage caused by misuse is not covered under warranty The following are some examples of misuse Pumping flammable explosive or corrosive fluids Pumping hot or volatile flu...

Страница 11: ...properly use the machine Are familiar with required safety devices The machine must not be accessed or operated by Children People impaired by alcohol or drugs Personal Protective Equipment PPE Wear...

Страница 12: ...al risks and hazards Personal Protective Equipment PPE Wear the following Personal Protective Equipment PPE while servicing or maintaining this machine Close fitting work clothes that do not hinder mo...

Страница 13: ...power cord to lift the pump Always use a dedicated ground leakage circuit breaker Be sure to install the ground wire securely Be sure to disconnect the power supply before handling or inspecting the...

Страница 14: ...to its center of gravity and weight If it is not lowered into place correctly it may fall and be damaged or cause injury When transporting the pump by hand be sure to employ manpower commensurate with...

Страница 15: ...Ref Description Ref Description 1 Lifting handle 9 Oil plug 2 Mechanical seal 10 Dust seal 3 Lubricant 11 Sleeve 4 Oil housing 12 Impeller 5 Coupling 13 Stirrer nut 6 Volute 14 Strainer 7 Gasket 15 O...

Страница 16: ...n representative at once 3 2 Residue Plate if equipped The residue plate kit contains the residue plate washers and bolts Reuse nuts from pump assembly 3 2 1 Remove the strainer 3 by loosening the thr...

Страница 17: ...the pump must be connected to a Ground Fault Interrupter GFI The pump must not be used when people are in the water Leakage of pump lubricants may cause pollution of water Proper plug must be provided...

Страница 18: ...readily visible 3 3 Preparing for Installation Before installing the pump at a work site you will need to have the following tools and instruments ready Insulation resistance tester megohmmeter AC vol...

Страница 19: ...Maintenance table 3 5 IInstalling the Float if equipped 3 5 1 Set the length of the float lead wire to the dimension indicated below Failure to set the correct lead wire length will lead to improper o...

Страница 20: ...hazard Incorrect wiring can lead to current leakage electrical shock or fire Electrical wiring should be connected by a qualified person in accordance with all applicable regulations Failure to obser...

Страница 21: ...use a dedicated power supply with a ground leakage circuit breaker Note The shape of the plug may differ from that shown in the illustration WARNING Personal injury hazard Electrical shock shorting fi...

Страница 22: ...t seal the wires completely in a molded protective sleeve to prevent electrical leakage electrical shock or fire Do not allow the cable assembly wires or power supply plug to become wet Make sure the...

Страница 23: ...otor insulation resistance Reference insulation resistance 20 MW or greater Note The reference insulation resistance 20 MW or greater is the value when the pump is new or has been repaired For the ref...

Страница 24: ...voltage COUNTERMEASURE If the supply voltage is outside the tolerance possible causes are the power supply capacity or an inadequate extension cable Look again at the wiring diagram and make sure the...

Страница 25: ...mp to avoid having it start unexpectedly when the power is restored presenting serious danger to people in the vicinity NOTICE Pay careful attention to the water level while the pump is operating Dry...

Страница 26: ...he US market CAUTION Damage to pump current leakage or electrical shock hazard Do not operate the pump below the C W L Continuous running Water Level indicated below Pump Model Continuous running Wate...

Страница 27: ...ion This will stop the pump 4 5 4 Repeat this cycle two or three more times to verify the operation Note The trial operation must be completed within one minute If the pump operates abnormally i e exh...

Страница 28: ...e regarding overhauls Pump Weekly Monthly Every 1000 hrs Every 2000 hrs Measure insulation resistance Reference insulation resistance 1MW or greater 1 Measure operating current Compare with rated curr...

Страница 29: ...eness may require that the unit be disassembled for repairs Please consult your nearest dealer or Wacker Neuson representative 5 2 Storage When the pump is out of use for an extended period wash it an...

Страница 30: ...Replace these using the recommended frequency as a guideline Ref Description Ref Description 1 Oil Inlet 3 Oil Plug 2 Gasket 4 Allen Wrench Pump Model Lubricant Capacity PST2 400 PSTF2 400 160 ml 5 4...

Страница 31: ...y in any other than the designated parts consult your nearest dealer or Wacker Neuson representative Improper repairs can result in electrical leakage electrical shock fire or water leaks After reasse...

Страница 32: ...a However drain oil if further disassembly and testing is required 5 4 1 Remove three nuts af and the suction strainer ac 5 4 2 Remove volute aa and volute gasket ah 5 4 3 While keeping the impeller w...

Страница 33: ...5 1 Visually inspect impeller w for corrosion wear or damage Worn impellers compromise peak performance 5 5 2 Visually inspect impeller key and rotor shaft keyway for signs of uneven wear 5 5 3 Visua...

Страница 34: ...and push impeller w onto rotor shaft 5 6 4 Secure with washer x lockwasher y and stirrer nut z 5 6 5 While holding the impeller from rotating tighten stirrer nut z 5 6 6 Position volute aa on suction...

Страница 35: ...or protector operates Impeller is clogged Remove debris Low voltage Provide the rated voltage or make sure the cable assembly extension is the proper standard Wrong power frequency Check the nameplate...

Страница 36: ...4 F Pump Impeller Semi Vortex Type Shaft Seal Double Mechanical Seal Bearing Shielded Ball Bearing Motor Specification Dry Submersible Induction Motor 2 Pole Insulation Class E Protection System Minia...

Страница 37: ...pump itself not including the cable assembly Part No PST2 400 PSTF2 400 Pump Electric Power V Ph Hz 110 1 60 Rated Current A 5 4 Starting Method Capacitor Run Bore mm in 50 2 Output kW Hp 0 40 0 50 Ma...

Страница 38: ...38 wc_td000034gb fm 6 3 Dimensions 6 3 1 Start range Stop range Minimum Maximum 185 7 3 250 9 8 330 13 0 PST2 400 PSTF2 400 wc_gr006191 385 15 2 40 1 6 328 12 9 90 3 5 120 4 8 255 10 1 207 8 1 340 13...

Страница 39: ...use use a time delay fuse with this pump Ref Description Ref Description 1 Capacitor 5 Frame grounding 2 Main coil 6 Ground 3 Auxiliary coil 8 Float switch normally open con tact 4 Miniature protector...

Страница 40: ...ematics PST2 400 40 wc_tx002025gb fm Wire Colors B Black V Violet Or Orange G Green W White Pr Purple L Blue Y Yellow Sh Shield P Pink Br Brown LL Light Blue R Red Cl Clear G Y Green Yellow T Tan Gr G...

Страница 41: ...wish to thank the members of the Association of Equipment Manufacturers for their invaluable contributions in preparing this Safety Manual NOTICE OF COPYRIGHT PROTECTION Copyright 2015 by the Associa...

Страница 42: ...y from the manufacturer Keep this safety manual and the manufacturer s manual s with the machine at all times Read and understand all applicable manuals before operating this pump or any other piece o...

Страница 43: ...the manufacturer be trained including actual operation and know the safety rules and regulations for the job site It is a good safety practice to point out and explain safety signs and practices to ot...

Страница 44: ...ill be expected to obey OSHA enforces federal laws within the United States that apply to the safe operation application and maintenance of equipment on some job sites It is the employer s responsibil...

Страница 45: ...ds If your pump is engine driven do not operate in the presence of toxic volatile or explosive gases Refer to the owner s manual or consult with the manufacturer for proper pump materials if you are t...

Страница 46: ...cool Remove the key to prevent fans from unexpectedly starting Ensure the coolers and engine compartment are clean and free from debris which could ignite and cause a fire If the machine is air coole...

Страница 47: ...hing nearby Carefully raise the forks and tilt the pump back slightly until it is approximately 4 6 inches off the ground and carefully transport as needed Check the overall height to ensure complianc...

Страница 48: ...tioning and their readings are within the operating range Run an Operating Check Do not use a machine that is not in proper operating condition It is your responsibility to check the condition of all...

Страница 49: ...se A pump should not be operated against a closed valve or other no ow conditions Refer to the pump manufacturer s recommended practice for start up operation and shut down procedures DO NOT close dow...

Страница 50: ...combustion engines in an enclosed area always make provisions to pipe exhaust fumes to the outside Exhaust Fumes Can Kill do not operate engine driv en pump equipment in a confined or enclosed space w...

Страница 51: ...plug connections lay in water Locate the pump so that the cord cannot fall into any water or be submerged by rising water unless the pump is designed for such use NEVER handle energized power cords w...

Страница 52: ...ou have the necessary skill information correct tools and proper equipment to do the job safely Be sure to maintain the equipment according to the manufacturer s instructions Regularly check the opera...

Страница 53: ...y of other working equipment Make sure there is adequate light ventilation and clearance Remove oil grease or water to eliminate any slippery surfaces Clean around the area to be serviced to minimize...

Страница 54: ...ength in feet 50 100 150 6 8 10 12 14 16 16 16 16 14 14 12 16 14 14 14 12 12 14 12 12 12 10 10 Check oil level ONLY when pump is cool USE ONLY recommended oil per manufacturer s recommendation INSPECT...

Страница 55: ...r appropriate eye protection Hydraulic fluid can cause permanent eye injury When venting or filling the hydraulic system loosen the filler cap slowly and remove it gradually Never reset any relief val...

Страница 56: ...ases especially when being charged Keep arcs sparks ames and lighted tobacco away Do not smoke near batteries Keep them away from arcs sparks and open flames Provide adequate ventilation Never check t...

Страница 57: ...e if necessary After testing shut down and check the work you performed Recheck all fluid levels before releasing the equipment for operation All parts should be inspected during repair and replaced i...

Страница 58: ...basic rules of safety will help to build good judgment in all situations Our objective is to help you develop establish and maintain good safety habits to make operating a portable pump easier and sa...

Страница 59: ...rveonderdelen Importante Para obter informa es sobre as pe as sobresselentes consulte o seu fornecedor da Wacker Neuson ou aceda ao site Web da Wacker Neuson em http www wackerneuson com Wa ne W celu...

Страница 60: ......

Отзывы: